| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
TMS417409A bảng dữ liệu(PDF) 13 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
TMS417409A bảng dữ liệu(HTML) 13 Page - National Semiconductor (TI) |
|
13 / 37 page ![]() TMS416409A, TMS417409A, TMS426409A, TMS427409A 4194304 BY 4-BIT EXTENDED DATA OUT DYNAMIC RANDOM-ACCESS MEMORIES SMKS893B – AUGUST 1996 – REVISED APRIL 1997 13 POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251–1443 capacitance over recommended ranges of supply voltage and operating free-air temperature, f = 1 MHz (see Note 3) PARAMETER MIN MAX UNIT Ci(A) Input capacitance, A0 – A11† 5 pF Ci(OE) Input capacitance, OE 7 pF Ci(RC) Input capacitance, CAS and RAS 7 pF Ci(W) Input capacitance, W 7 pF Co Output capacitance‡ 7 pF † A11 is NC (no internal connection) for TMS417409A and TMS427409A. ‡ CAS and OE = VIH to disable outputs NOTE 3: VCC = NOM supply voltage ± 10%, and the bias on pins under test is 0 V. switching characteristics over recommended ranges of supply voltage and operating free-air temperature (see Note 4) PARAMETER ’41x409A-50 ’42x409A-50 ’41x409A-60 ’42x409A-60 ’41x409A-70 ’42x409A-70 UNIT MIN MAX MIN MAX MIN MAX tAA Access time from column address (see Note 5) 25 30 35 ns tCAC Access time from CAS (see Note 5) 13 15 18 ns tCPA Access time from CAS precharge (see Note 5) 28 35 40 ns tRAC Access time from RAS (see Note 5) 50 60 70 ns tOEA Access time from OE (see Note 5) 13 15 18 ns tCLZ Delay time, CAS to output in low impedance 0 0 0 ns tREZ Output buffer turn off delay from RAS (see Note 6) 3 13 3 15 3 18 ns tCEZ Output buffer turn off delay from CAS (see Note 6) 3 13 3 15 3 18 ns tOEZ Output buffer turn off delay from OE (see Note 6) 3 13 3 15 3 18 ns tWEZ Output buffer turn off delay from W (see Note 6) 3 13 3 15 3 18 ns NOTES: 4. With ac parameters, it is assumed that tT = 2 ns. 5. For TMS42x409A, access times are measured with output reference levels of VOH = 2 V and VOL = 0.8 V. 6. The maximum values of tREZ, tCEZ, tOEZ, and tWEZ are specified when the output is no longer driven. Data in should not be driven until one of the applicable maximum specifications is satisfied. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |