228 / 236 page ![]() TMS320DM6441 SPRS359E – SEPTEMBER 2006 – REVISED AUGUST 2010 www.ti.com 6.25.1 Host-Port Interface (HPI) Electrical Data/Timing Table 6-116. Timing Requirements for Host-Port Interface Cycles(1) (2) (see Figure 6-81 through Figure 6-82) 1.05 V and 1.2 V NO. UNIT MIN MAX 1 tsu(SELV-HSTBL) Setup time, select signals(3) valid before HSTROBE low 5 ns 2 th(HSTBL-SELV) Hold time, select signals(3) valid after HSTROBE low 2 ns 3 tw(HSTBL) Pulse duration, HSTROBE low 15 ns 4 tw(HSTBH) Pulse duration, HSTROBE high between consecutive accesses 2P ns 12 tsu(HDV-HSTBH) Setup time, host data valid before HSTROBE high 5 ns 13 th(HSTBH-HDV) Hold time, host data valid after HSTROBE high 0 ns Hold time, HSTROBE high after HRDY low. HSTROBE should not 14 th(HRDYL-HSTBH) beinactivated until HRDY is active (low); otherwise, HPI writes will not 2 ns complete properly. (1) HSTROBE refers to the following logical operation on HCS, HDS1, and HDS2: [NOT(HDS1 XOR HDS2)] OR HCS. (2) P = 1/CPU clock frequency in ns. For example, when running parts at 405 MHz, use P = 2.47 ns. (3) Select signals include: HCNTL[1:0] and HR/W. For HPI16 mode only, select signals also include HHWIL. Table 6-117. Switching Characteristics Over Recommended Operating Conditions During Host-Port Interface Cycles(1) (see Figure 6-81 through Figure 6-82) 1.05 V and 1.2 V NO. PARAMETER UNIT MIN MAX 6 td(HSTBL-HRDYH) Delay time, HSTROBE low to HRDY high(2) 0 12 ns 7 td(HSTBL-HDLZ) Delay time, HSTROBE low to HD low impedance for an HPI read 2 ns 8 td(HDV-HRDYL) Delay time, HD valid to HRDY low 0 ns 9 toh(HSTBH-HDV) Output hold time, HD valid after HSTROBE high 1.5 ns 15 td(HSTBH-HDHZ) Delay time, HSTROBE high to HD high impedance 4 ns 16 td(HSTBL-HDV) Delay time, HSTROBE low to HD valid (HPI16 mode, 2nd half-word only) 15 ns 20 td(HCSL-HRDYH) Delay time, HCS low to HRDY high 0 12 ns (1) HSTROBE refers to the following logical operation on HCS, HDS1, and HDS2: [NOT(HDS1 XOR HDS2)] OR HCS. (2) This parameter is used during HPID reads and writes. For reads, at the beginning of the first half-word transfer (HPI16) on the falling edge of HSTROBE, the HPI sends the request to the EDMA3 internal address generation hardware, and HRDY remains high until the EDMA3 internal address generation hardware loads the requested data into HPID. For writes, HRDY goes high if the internal write buffer is full. 228 Peripheral and Electrical Specifications Copyright © 2006–2010, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s): TMS320DM6441 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |