49 / 129 page ![]() DocID029656 Rev 2 49/129 ST25R3911B Functional overview 71 During execution of the direct command Measure Phase the transmitter and Phase Detector are enabled, the Phase Detector output is multiplexed on the input of A/ D converter, which is set in relative mode. Since the A/D converter range is from 1/6 VSP_A to 5/6 VSP_A the actual phase detector range is from 30º to 150º. Values below 30º result in FFh, while values above 150º result in 00h. One LSB of the A/D conversion output represents 0.13% of carrier frequency period (0.468°). The result of A/D conversion is in case of 90º phase shift in the middle of range (1000 0000b or 0111 1111b). A value higher than 1000 0000b means that phase detector output voltage is higher than VSP_A/2, which corresponds to case with phase shift lower than 90º. In the opposite case, when the phase shift is higher than 90º, the result of A/D conversion is lower than 0111 1111b. For example, the phase difference of 135º shown in Figure 7 results in 0.75 VSP_A, result stored in A/D converter is 31d (1Fh). The phase measurement result can be calculating using the following formulas: • 0º ≤ φ ≤ 30º: result = 255 (decimal) • 30º < φ < 150º: angle (in º) = 30 + [(255 - u_angle) / 255) * 120] • 150º ≤ φ ≤ 180º: result = 0 (decimal) Duration time: 25 μs max. This command is accepted in case en (bit 7 of the Operation Control Register) is set and Xtal oscillator frequency is stable. Direct command chaining is not possible. IRQ due to termination of direct command is produced after command execution is terminated. Clear RSSI The receiver automatically clears the RSSI bits in the RSSI Display Register and starts to measure the RSSI of the received signal when the signal rx_on is asserted. Since the RSSI bits store peak value (peak-hold type) the variations of the receiver input signal will not be followed (this may happen in case of long messages or test procedures). The direct command Clear RSSI clears the RSSI bits in the RSSI Display Register, and the RSSI measurement is restarted (in case, of course, rx_on is still high). This command is accepted in case en (bit 7 of the Operation Control Register) is set and Xtal oscillator frequency is stable. Direct command chaining is possible. IRQ due to termination of direct command is not produced. Transparent Mode Enters in the Transparent mode. The Transparent mode is entered on the rising edge of signal /SS and is maintained as long as signal /SS is kept high. This command is accepted when en (bit 7 of the Operation Control Register) is set and Xtal oscillator frequency is stable. Calibrate Capacitive Sensor This command calibrates the Capacitive Sensor. See Section 1.1.5: Capacitive sensor for more details. Duration time: 3 ms max. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |