| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
CBLRLC00 bảng dữ liệu(PDF) 13 Page - Red Lion Controls. Inc |
|
|
|||||||||||||||||||||||||||||
CBLRLC00 bảng dữ liệu(HTML) 13 Page - Red Lion Controls. Inc |
|
13 / 28 page ![]() 13 TEMPERATURE COOL HEAT SETPOINT -100% O2 +100% O1 2X PROPORTIONAL BAND % OUTPUT POWER O1 +100% SETPOINT DEADBAND NEGATIVE VALUE COOL RELATIVE GAIN = .5 .5 1 2 RELATIVE GAIN O2 -100% TEMPERATURE HEAT % OUTPUT POWER TEMPERATURE HEAT SETPOINT -100% O2 +100% O1 DEADBAND POSITIVE VALUE RELATIVE GAIN 21 .5 RELATIVE GAIN = .5 COOL % OUTPUT POWER HEAT/COOL RELATIVE GAIN FIGURES Heat/Cool Deadband = 0 Heat/Cool Deadband < 0 Heat/Cool Deadband > 0 STEP 14 PROGRAMMING THE COOLING To enable Cooling in Heat/Cool applications, the Alarm 2 Action must first be set for Cooling. When set to cooling, the output no longer operates as an alarm but operates as an independent cooling output. The OP2 terminals are the same as AL2. Cooling output power ranges from -100% (full cooling) to 0% (no cooling, unless a heat/cool deadband overlap is used). The Power Limits in the Output category also limits the cooling power. Cycle Time (40141/40241): This cycle time functions like the OP1 Output Cycle Time but allows independent cycle time for cooling. A setting of zero will keep output OP2 off. The status of OP2 can be read through registers (40016/40032). Relative Gain (40142/40242): This defines the gain of the cooling relative to the heating. It is generally set to balance the effects of cooling to that of heating. This is illustrated in the Heat/Cool Relative Gain Figures. A value of 0.0 places the cooling output into On/Off Control. This may be done independent of the OP1 Output PID or On/Off Control Modes. Deadband (40143/40243): This defines the area in which both heating and cooling are active (negative value) or the deadband area between the bands (positive value). If a heat/cool overlap is specified, the percent output power is the sum of the heat power (OP1) and the cool power (OP2). If Relative Gain is zero, the cooling output operates in the On/Off Control Mode, with the Deadband value becoming the cooling output hysteresis (positive value only). This is illustrated in the On/Off Control Mode section. For most applications, set this parameter to 0.0 prior to starting Auto-Tune. After the completion of Auto-Tune, this parameter may be changed. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |