3 / 12 page ![]() AD8233CB-EBZ User Guide UG-1016 Rev. 0 | Page 3 of 12 EVALUATION BOARD HARDWARE A simplified schematic is shown in Figure 2 of the AD8233CB- EBZ evaluation board default configuration. See the Evaluation Board Component Selection section for the full schematic. The expected output signal is measured at the OUT terminal, shown in Figure 3. +VS AD8233 +VS GND OUT OPAMP– REFOUT OPAMP+ SW REFIN IAOUT HPSENSE HPDRIVE +IN –IN RLD RLDFB FR SDN AC/DC G = 100 LEADS-OFF DETECTION A1 A2 10kΩ 10kΩ 150kΩ S1 S2 A3 A5 B5 C5 C4 D5 D4 D3 C3 D2 D1 C1 C2 B1 B2 B3 A1 A2 A3 B4 A4 +VS IAOUT HIGH PASS TO OPAMP STAGE HIGH PASS SECOND-ORDER LOW PASS AND GAIN ELECTRODES OPTIONAL DRIVEN LEAD ELECTRODE LOD RLD SDN FR SDN AC/DC VOUT 10MΩ 10MΩ 180kΩ 180kΩ 499kΩ 1nF 10MΩ 10MΩ 10MΩ 1MΩ 100kΩ 1MΩ 200kΩ 100kΩ 0.22µF 10nF 22nF 0.22µF 10µF RLD SDN C Figure 2. AD8233CB-EBZ Default Configuration 0.5V/DIV 500ms/DIV Figure 3. AD8233CB-EBZ Expected Output Signal Measured at the OUT Terminal QUICK START GUIDE The AD8233CB-EBZ evaluation board ships with a default configuration of a three-electrode system that connects to the hands of a subject. For a three-electrode configuration, verify the switches and jumpers are set to the default values shown in Table 1. Various other configurations are shown in Table 2. Table 1. Default Switch and Jumper Settings Label Position Setting S1 FR_DIS Fast restore disabled S2 DC DC leads off detection S3 EN Operation enabled S4 RLD_EN RLD enabled Input Bias Selection P4, P6, P7 Three-electrode dc REFIN Resistor Divider EN P8, P9 REFIN is set to +VS/2 Setup Procedure Take the following steps to set up the AD8233CB-EBZ evaluation board: 1. Connect a power supply common to the GND terminal on the evaluation board. Connect a +3 V supply voltage at the +VS terminal. 2. Connect the left arm (LA) terminal and the right arm (RA) terminal to a signal source such as an ECG signal generator. 3. Connect the right leg (RL) terminal to a signal source such as an ECG signal generator. The RLD is available via the RL terminal. 4. Alternatively, connect a sensor cable (not included) to the 3.5 mm electrode jack and connect the electrodes to a signal source such as an ECG signal generator. 5. The output signal is available on the OUT terminal. The expected output signal is shown in Figure 3. Precaution When Using the AD8233CB-EBZ For safety reasons, Analog Devices recommends evaluating the AD8233 with an ECG signal source instead of a live subject. Although the LA, RA, and RL electrode terminals are equipped with current-limiting resistors (R6 and R7), these resistors are not a comprehensive patient protection system. The resistors may not protect against supply line transients or leakage currents coming through power and acquisition systems. The user is fully responsible for understanding and applying all the safety guidelines and regulations that apply to medical equipment. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |