  RCP-1UI Datasheet HTML 1Page - Mean Well Enterprises Co., Ltd. RCP-1UI Datasheet HTML 2Page - Mean Well Enterprises Co., Ltd. RCP-1UI Datasheet HTML 3Page - Mean Well Enterprises Co., Ltd. RCP-1UI Datasheet HTML 4Page - Mean Well Enterprises Co., Ltd. RCP-1UI Datasheet HTML 5Page - Mean Well Enterprises Co., Ltd. RCP-1UI Datasheet HTML 6Page - Mean Well Enterprises Co., Ltd.  
Zoom Inzoom in Zoom Outzoom out
 6 / 6 page
background image
Pin No.
Function
Description
1,8,15
2,9,16
3,10,17
4,11,18
5,12,19
7
23
25
14
6
Remote
ON-OFF
AC-OK
DC-OK
V-TRIM
T-ALARM
GND-AUX
SCL
-V
CS
+5V-AUX
Each unit can separately turn the output on and off by electrical or dry contact between Remote ON-OFF A,B,C(pin 1,8,15) and -S(pin 21). Short: ON, Open:OFF.
Low : When input voltage is
82Vrms +/-4V.
≧
High : When input voltage in
82Vrms +/-4V.
≦
High : When Vout
80%+/-5%.
≦
Low : When Vout
80%+/-5%
≧
Connection for output voltage programming.
High : When the internal temperature is within safe limit.
Low : 10
below the thermal shut down limit.
℃
Auxiliary voltage output GND.
The signal return is isolated from the output terminals (+V & -V).
Serial clock used in the I C interface option. Refer to the Instruction Manual.
Negative output voltage.
Current sharing signal.
When units are connected in parallel, the CS pins of the units should be connected to allow current balance between units.
Auxiliary voltage output, 4.3~5.3V, referenced to GND-AUX(pin 7).
The maximum load current is 0.3A. This output has the built-in "Oring diodes" and is not controlled by the remote ON/OFF control.
2
20
21
+S
-S
Positive sensing for Remote Sense.
Negative sensing for Remote Sense.
22
+V
Positive output voltage.
24
SDA
Serial data used in the I C interface option. Refer to the Instruction Manual.
2
※ IN/OUT Connector Pin No. Assignment(
) : D-Type Right Angle 25 positions(female type)
CN500
File Name:RCP-1U Rack System-SPEC 2016-07-26
Please refer to the manual of RCP-1U system.
Installation Manual
1000 ~ 3000W 1U Distributed Power System
RCP-1U Rack System
1
14
13
25



Html Pages

1 2 3 4 5 6


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com