| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
OBR4600 bảng dữ liệu(PDF) 2 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
OBR4600 bảng dữ liệu(HTML) 2 Page - List of Unclassifed Manufacturers |
|
2 / 4 page ![]() OBRTM is a trademark of Luna Innovations Incorporated. ©Luna Innovations Incorporated, Roanoke, VA All rights reserved. OBR 4600 LTOBR4600 REV. 004 02/13/2014 PARAMETER SPECIFICATION UNITS Maximum Device Length: Standard Mode 30 or 70 meters Long Range Mode12 2000 meters Spatial Resolution (two-point)1: 10 µm over 30 meters 20 µm over 70 meters 1 mm over 2 km Dead Zone: Equals 2-pt spatial resolution Wavelength Range2: 1270-1340 or 1525-1610 nm Wavelength: Resolution (max) 0.02 pm Accuracy3 ±1.5 pm Integrated Return Loss Characteristics: Dynamic range4 70 dB Total range 0 to -125 dB Sensitivity -130 dB Resolution5 ±0.05 dB Accuracy5 ±0.10 dB Integrated Insertion Loss Characteristics: Dynamic range6 18 dB Resolution5 ±0.05 dB Accuracy5 ±0.10 dB Group Delay: Accuracy 1.0 ps Distributed Sensing7,12,13: Spatial Resolution8 ±1.0 cm Temperature Resolution9 ±0.1 C Strain Resolution9 ±1.0 µstrain Measurement Timing10 Standard Fast11 Spot Scan11 5 nm scan time 3 1.6 0.3 s Time vs. wavelength range 2.1 s+0.14 s/nm 1.3 s+0.06 s/nm 0.15 s+0.02 s /nm - Long Range (2 km) Scan Time 20 s Specifications are for single-mode operation. For multimode operation, specifications are nominal. 1 Over entire length range. 2 Ranges are nominal. 3 Accuracy maintained by an internal NIST-traceable HCN gas cell. 4 For the 2000 m option, return loss dynamic range is 60 dB. 5 With integration width of 0.5 m 6 The insertion loss dynamic range is the one-way loss that can be suffered before the scatter level of standard SMF (~ -100 dB/mm) is lower than the noise floor (~ -118 dB/mm). 7 Distributed sensing uses Rayleigh spectral shift method and is relative to reference scan. 8 Spatial resolutions listed are ideal to get the temperature and strain resolutions listed; they are not minimums or maximums. 9 Temperature and strain resolutions are calculated from spectral shift of Rayleigh scatter using 1 GHz = 0.8 C = 6.58 µStrain. [Othonos and K. Kalli, Fiber Bragg Gratings (Artech House, Boston, 1999)]. 10 Combined scan and analysis time in high-resolution mode. Times are for 30 m scan mode. 11 Times are with laser tuning speed set at 100 nm/s. 12 Extended range mode and distributed sensing are upgrade options 13 Maximum standard sensing length is 70m. Limited sensing is available in extended range mode. Contact your Luna representative for more information. CLASS 1 LASER PRODUCT SpecificationsT |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |