18 / 61 page ![]() VDP 3108 ADVANCE INFORMATION MICRONAS INTERMETALL 18 10 bit DAC Video 3.8 mA blank & timing 8 bit ADC measurm. 9 bit U/I–DAC 3.8 mA clamp key analog R in Sense analog R out analog G out analog B out analog G in analog B in digital R in H V measurem. 10 9 bit DAC 1.5 mA digital G in digital B in 9 bit DAC 2.2 mA blanking 750 uA 10 bit DAC Video 3.8 mA 10 bit DAC Video 3.8 mA 9 bit U/I–DAC 3.8 mA clamp 9 bit U/I–DAC 3.8 mA clamp 9 bit DAC 2.2 mA blanking 750 uA 9 bit DAC 2.2 mA blanking 750 uA 9 bit DAC 1.5 mA 9 bit DAC 1.5 mA Input I/O Fig. 2–22: Analog back end 9 bit DAC 1.5 mA 9 bit DAC 1.5 mA 9 bit DAC 1.5 mA fast blank in white drive R white drive G white drive B int . brightness ext. contrast ext. brightness FP Interface 2.5.1. CRT Measurement and Control The display processor is equipped with an 8 bit PDM- ADC for all measuring purposes. The ADC is connected to the Sense input pin, the input range is 0...1.5V. The bandwidth of the PDM filter can be selected; the mea- surement window is 19/9.5 µs for small/large bandwidth setting. The input impedance is more than 1 M Ω. Cutoff and white drive current measurement is carried out during the vertical blanking interval. It is always using the small bandwidth setting. The current range for the cutoff measurement is set by connecting a sense resis- tor to then MADC input. For the whitedrive measure- ment, the range is set by using a sense resistor and the range select switch 2 output pin. During the active pic- ture the minimum and maximum beam current is mea- sured. The measurement range can be set by using the range select switch pin. The timing window of this mea- surement is programmable. The intention is to automati- cally detect letterbox transmission or to measure the ac- tual beam current. All control loops are closed via the external control microprocessor. In each field two sets of measurements can be taken: a) The picture tube measurement returns results for |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |