| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
LPS366-M bảng dữ liệu(PDF) 1 Page - Artesyn Technologies |
|
|
|||||||||||||||||||||||||||||
LPS366-M bảng dữ liệu(HTML) 1 Page - Artesyn Technologies |
|
1 / 3 page ![]() POWER LPS360-M Series 360 Watt AC-DC Power Supply Total Power: 200 - 360 W Input Voltage: 90 - 264 Vac 120 - 300 Vdc Outputs: Single SPECIAL FEATURES Medical and ITE safeties Active power factor correction 3” x 5” footprint Less than 1U high EN61000-3-2 compliant Remote sense Power fail Adjustable main output Level B Conducted EMI - Class I or Class II inputs Overvoltage protection Overload protection Thermal overload protection 12 V fan output LPX200 enclosure kit available 5 V Standby output Remote Inhibit PMBus commands RoHS compliant Digital I2C interface Designed to meet Class I and Class II Dual AC fuses Suitable for BF Type applications SAFETY TUV 60950, 60601-1 UL 60950, 60601-1 cULus 60950, 60601-1 CB Certificate & report CE Mark (LVD & EMC) CCC Approval Electrical Specifications Input Input range 90 - 264 Vac; 120 - 300 Vdc Frequency 47 - 63 Hz Inrush current 50 A max., cold start @ 25 °C Efficiency Up to 93% at full load EMI/RFI FCC Class B conducted; CISPR22 Class B conducted; EN55022 Class B conducted; VDE0878PT3 Class B conducted Power factor 0.99 typical Safety ground leakage current 150 µA @ 132 Vac, 60 Hz for class I, 300 µA @ 264 Vac, 60 Hz for class II Output Maximum power 200 - 240 W (see de-rating) for convection, 360 W with 400 LFM of forced air Adjustment range 12 V and 24 V models, -0%, +15%; 15 V and 48 V models, -5%, +10%; 36 V model, -15%, +0% Standby output 5 V @ 1A convection, 2 A with forced air Fan output 12 V @ 0.5 A convection, 1 A forced air Hold-up time 20 ms @240 W, 220 Vac input; 12 ms @ 360 W Overload protection Short circuit protection on all outputs. Case overload protected @ 110 - 160% above rating Overvoltage protection 15 - 50% above nominal output Logical Control Power failure Open collector logic signal goes high 100 - 500 msec after main output; it goes low at least 6 msec before loss of regulation Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Low Power Data Sheet |
Số phần tương tự - LPS366-M |
|
Mô tả tương tự - LPS366-M |
|
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |