công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

AS4C64M16D3 bảng dữ liệu(PDF) 49 Page - Alliance Semiconductor Corporation

tên linh kiện AS4C64M16D3
Giải thích chi tiết về linh kiện  AS4C64M16D3
PDF  89 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
nhà sản xuất  ALSC [Alliance Semiconductor Corporation]
Trang chủ  https://www.alliancememory.com
Logo ALSC - Alliance Semiconductor Corporation

AS4C64M16D3 bảng dữ liệu(HTML) 49 Page - Alliance Semiconductor Corporation

Back Button AS4C64M16D3 Datasheet HTML 45Page - Alliance Semiconductor Corporation AS4C64M16D3 Datasheet HTML 46Page - Alliance Semiconductor Corporation AS4C64M16D3 Datasheet HTML 47Page - Alliance Semiconductor Corporation AS4C64M16D3 Datasheet HTML 48Page - Alliance Semiconductor Corporation AS4C64M16D3 Datasheet HTML 49Page - Alliance Semiconductor Corporation AS4C64M16D3 Datasheet HTML 50Page - Alliance Semiconductor Corporation AS4C64M16D3 Datasheet HTML 51Page - Alliance Semiconductor Corporation AS4C64M16D3 Datasheet HTML 52Page - Alliance Semiconductor Corporation AS4C64M16D3 Datasheet HTML 53Page - Alliance Semiconductor Corporation Next Button
Zoom Inzoom in Zoom Outzoom out
 49 / 89 page
background image
AS4C64M16D3
Confidential
49
Rev. 3.0
Aug. /2014
Power-Down Modes
 Power-Down Entry and Exit
Power-Down is synchronously entered when CKE is registered low (along with NOP or Deselect command). CKE
is not allowed to go low while mode register set command, MPR operations, ZQCAL operations, DLL locking or
read/write operation are in progress. CKE is allowed to go low while any of other operation such as row activation,
precharge or auto precharge and refresh are in progress, but power-down IDD spec will not be applied until
finishing those operation.
The DLL should be in a locked state when power-down is entered for fastest power-down exit timing. If the DLL is
not locked during power-down entry, the DLL must be reset after exiting power-down mode for proper read
operation and synchronous ODT operation. DRAM design provides all AC and DC timing and voltage specification
as well proper DLL operation with any CKE intensive operations as long as DRAM controller complies with DRAM
specifications.
During Power-Down, if all banks are closed after any in progress commands are completed, the device will be in
precharge Power-Down mode; if any bank is open after in progress commands are completed, the device will be in
active Power-Down mode.
Entering Power-down deactivates the input and output buffers, excluding CK, CK, ODT, CKE, and RESET#
.
To protect DRAM internal delay on CKE line to block the input signals, multiple NOP or Deselect commands are
needed during the CKE switch off and cycle(s) after, this timing period are defined as tCPDED. CKE_low will result
in deactivation of command and address receivers after tCPDED has expired.
Table 23. Power-Down Entry Definitions
Status of DRAM
MRS bit A12
DLL
PD Exit Relevant Parameters
Active
(A Bank or more open)
Don't Care
On
Fast
tXP to any valid command.
Precharged
(All Banks Precharged)
0
Off
Slow
tXP to any valid command. Since it is in
precharge state, commands here will be ACT,
AR, MRS/EMRS, PR or PRA.
tXPDLL to commands who need DLL to
operate, such as RD, RDA or ODT control line.
Precharged
(All Banks Precharged)
1
On
Fast
tXP to any valid command.
Also the DLL is disabled upon entering precharge power-down (Slow Exit Mode), but the DLL is kept enabled
during precharge power-down (Fast Exit Mode) or active power-down. In power-down mode, CKE low, RESET#
high, and a stable clock signal must be maintained at the inputs of the DD3 SDRAM, and ODT should be in a valid
state but all other input signals are “Don’t care” (If RESET# goes low during Power-Down, the DRAM will be out of
PD mode and into reset state).
CKE low must be maintain until tCKE has been satisfied. Power-down duration is limited by 9 times tREFI of the
device. The power-down state is synchronously exited when CKE is registered high (along with a NOP or Deselect
command).CKE high must be maintained until tCKE has been satisfied. A valid, executable command can be
applied with power-down exit latency, tXP and/or tXPDLL after CKE goes high. Power-down exit latency is defined
at AC spec table of this datasheet.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com