| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
FPD85310 bảng dữ liệu(PDF) 24 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
FPD85310 bảng dữ liệu(HTML) 24 Page - National Semiconductor (TI) |
|
24 / 29 page ![]() APPENDIX A: GPO Programming Examples The GPO control generation is based on the internal line count and pixel count shown in Figure 7 and Figure 8.Two programmable registers (Vertical Start and Vertical Duration) control the vertical component of the control signal. This es- tablishes at what line and for how many lines the control sig- nal will be active. Likewise, two programmable registers (Horizontal Start and Horizontal Duration) control the hori- zontal component of the control signal. The Horizontal regis- ter values determine at what pixel count the signal goes ac- tive and for how many pixel counts the signal stays active during each line. The Vertical Component enables the signal for however many lines programmed for and the Horizontal Component generates pulses within that vertical time period. Generally the following types of signals are generated: 1. DC (either 1 or 0) 2. A pulse every line 3. A pulse once a frame (either in pixels or lines) 4. Pulsed during active video (pulses are blanked during vertical blanking period of frame) Table 5 describes the programming requirements for general types of pulses generated. The GPO’s also have a “toggle mode”. This provides the ca- pability to generate a “REVERSAL” signal used in most LCD applications. Bit 1 of the Control register is set toa1toen- able toggle mode operation. The GPO is programmed so that a rising edge is produced when the control signal is re- quired to toggle. This generally occurs once each line. Also, the # of edges generated per frame is programmed to be an odd #. This ensures that the control signal will alternate po- larity from frame to frame. Examples of GPO programming to produce specific control signals are included in the following pages. TABLE 5. GPO Pulse Generation Vertical Start Vertical Duration Horizontal Start Horizontal Duration GPO Output =don’t care =0 =0 =0 Stuck 0 (When Output Polarity = 0) Stuck 1 (When Output Polarity = 1) Polarity control is in GPO Control Register bit 0 =don’t care =0 #A =0 Stuck 1 (When Output Polarity = 0) Stuck 0 (When Output Polarity = 1) Polarity control is in GPO Control Register bit 0 =don’t care =0 #A #B (Note 29) Pulse is generated every line beginning at ∼#A 32 MHz clocks from start of output line and lasting for #B 32 MHz clocks #A #B #C =0 Pulse begins at line #A , clock #C and continues to line #(A+B) pixel #C (multi-line pulse) #A #B #C #D (Note 29) Pulse generation begins at line A and continues for #B lines. Each pulse begins at ∼pixel #C and lasts for D counts Note 29: Pulses will occur every other line if Horizontal Duration is greater than a line time. www.national.com 24 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |