| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
AD5253EVAL bảng dữ liệu(PDF) 17 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD5253EVAL bảng dữ liệu(HTML) 17 Page - Analog Devices |
|
17 / 28 page ![]() AD5253/AD5254 Rev. 0 | Page 17 of 28 1 READ S 0 1 0 1 1 A D 1 A D 0 1 A P A RDAC_N OR EEMEM_N REGISTER DATA RDAC_N + 1 OR EEMEM_N + 1 REGISTER DATA SLAVE ADDRESS (N BYTES + ACKNOWLEDGE) A Figure 29. RDAC Current Read. Restricted to Previously Selected Address Stored in the Register. P S SLAVE ADDRESS 0 WRITE SLAVE ADDRESS INSTRUCTIONAL AND ADDRESS A 1 S REPEATED START 1 READ A 0A (N BYTES + ACKNOWLEDGE) RDAC OR EEMEM DATA A/A Figure 30. RDAC or EEMEM Random Read 0 WRITE 1 CMD S 0 1 0 1 1 A D 1 A D 0 0 A C 3 C 2 C 1 C 0 A 2 A 1 A 0 A P RDAC SLAVE ADDRESS CMD/ REG Figure 31. RDAC Quick Command Write (Dummy Write) From Master to Slave From Slave to Master S = Start Condition P = Stop Condition A = Acknowledge (SDA Low) A = Not Acknowledge (SDA High) AD1, AD0 = I2C Device Address Bits. Must match with the logic states at Pins AD1, AD0. R/W = Read Enable Bit, Logic High/Write Enable Bit, Logic Low CMD/REG = Command Enable Bit, Logic High/Register Access Bit, Logic Low C3, C2, C1, C0 = Command Bits A2, A1, A0 = RDAC/EEMEM Register Addresses Table 9. RDAC-to-EEMEM Interface and RDAC Operation Quick Command Bits (CMD/REG = 1, A2 = 0) C3 C2 C1 C0 Command Description 0 0 0 0 NOP 0 0 0 1 Restore EEMEM (A1, A0) to RDAC (A1, A0)1 0 0 1 0 Store RDAC (A1, A0) to EEMEM (A1, A0) 0 0 1 1 Decrement RDAC (A1, A0) 6 dB 0 1 0 0 Decrement All RDACs 6 dB 0 1 0 1 Decrement RDAC (A1, A0) One Step 0 1 1 0 Decrement All RDACs One Step 0 1 1 1 Reset: Restore EEMEMs to All RDACs 1 0 0 0 Increment RDACs (A1, A0) 6 dB 1 0 0 1 Increment All RDACs 6 dB 1 0 1 0 Increment RDACs (A1, A0) One Step 1 0 1 1 Increment All RDACs One Step 1 1 0 0 Reserved : : : : 1 1 1 1 Reserved RDAC/EEMEM Quick Commands AD5253/AD5254 feature 12 quick commands that facilitate easy manipulation of RDAC wiper settings as well as provide RDAC-to-EEMEM storing and restoring functions. The command format is shown in Figure 31, and the command descriptions are shown in Table 9. When using a quick command, issuing a third byte is not needed but is allowed. The quick commands Reset and Store RDAC to EEMEM require acknowledge polling to determine whether the command has finished executing. 1 This command leaves the device in the EEMEM read power state, which consumes power. Issue the NOP command to return the device to the idle state. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |