29 / 41 page ![]() Application Hints (Continued) be queried to see what mode it is in. This is done by issuing a “read STATUS register” instruction to the ADC. When bit 9 of the status register is high, the ADC is in test mode; when bit 9 is low the ADC, is in user mode. As an alternative to cy- cling the power supply, an instruction sequence may be used to return the device to user mode. This instruction sequence must be issued to the ADC using CS. The following table lists the instructions required to return the device to user mode: Instruction DI Data DI0 DI1 DI2 DI3 DI4 DI5 DI6 DI7 TEST MODE H X X X HHHH Reset Test Mode Instructions LLLL H H H L L L L LHLHL L L L LHLH H USER MODE LLLL HHHH Power Up L L L LHLHL Set DO with H or without or L L L H H L H Sign L Set H H Acquisition or or L L H H H L Time L L Start HHHH HHH a orororor L or or or Conversion LLLL LLL X = Don’t Care After returning to user mode with the user mode instruction the power up, data with or without sign, and acquisition time instructions need to be resent to ensure that the ADC is in the required state before a conversion is started. 1.7 Reading the Data Without Starting a Conversion The data from a particular conversion may be accessed without starting a new conversion by ensuring that the CONV line is taken high during the I/O sequence. See the Read Data timing diagrams. Table 5 describes the operation of the CONV pin. 2.0 DESCRIPTION OF THE ANALOG MULTIPLEXER For the ADC12138, the analog input multiplexer can be con- figured with 4 differential channels or 8 single ended chan- nels with the COM input as the zero reference or any combi- nation thereof (see Figure 9). The difference between the voltages on the V REF + and V REF − pins determines the input voltage span (V REF). The analog input voltage range is 0 to V A +. Negative digital output codes result when V IN − > V IN +. The actual voltage at V IN − or V IN + cannot go below AGND. CH0, CH2, CH4, and CH6 can be assigned to the MUX- OUT1 pin in the differential configuration, while CH1, CH3, CH5, and CH7 can be assigned to the MUXOUT2 pin. In the differential configuration, the analog inputs are paired as fol- lows: CH0 with CH1, CH2 with CH3, CH4 with CH5 and CH6 with CH7. The A/DIN1 and A/DIN2 pins can be assigned positive or negative polarity. With the single-ended multiplexer configuration CH0 through CH7 can be assigned to the MUXOUT1 pin. The COM pin is always assigned to the MUXOUT2 pin. A/DIN1 is assigned as the positve input; A/DIN2 is assigned as the negative in- put. (See Figure 10). DS012079-34 DS012079-35 FIGURE 9. Differential Configuration DS012079-36 A/DIN1 and A/DIN2 can be assigned as the + or − input Single-Ended Configuration DS012079-37 A/DIN1 is + input A/DIN2 is − input FIGURE 10. www.national.com 29 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |