29 / 37 page ![]() L6362A Protection and diagnostic DocID027660 Rev 4 29/37 11.6 OL (overload) pin The integrated open drain transistor is active (turn-on) in case of overload conditions. Overload is detected when the output current exceeds the IOLS-PEAK or IOHS-PEAK threshold. The open drain transistor is active with a small delay (tOL), after the overload condition is detected. Overload is not detected when EN/DIAG pin is at a low logic level. Overload is not detected in cut-off conditions: if the output stage remains in a current limitation (OL) condition for a time longer than the tdOUT delay, the output stage is turned off (cut-off condition) and the OL pin is released. The output stage is restarted after the trOUT restart time. 11.7 Reverse polarity protection The integrated reverse polarity protection (RPP) avoids any damage in the IC in case of wrong connection of its pins to the supply rail lines. These protected pins, despite reverse polarity, are: VCC, GND, OUTH, OUTL and I/Q. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |