| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
SHT3X bảng dữ liệu(PDF) 4 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
SHT3X bảng dữ liệu(HTML) 4 Page - List of Unclassifed Manufacturers |
|
4 / 13 page ![]() Datasheet SHT3x-ARP www.sensirion.com May 2015 - Version 0.93 4/13 1.2 Temperature Sensor Performance Parameter Condition Value Units Accuracy tolerance1 Typ. 10 to +55 0.3 °C Repeatability2 0.1 °C Resolution Typ. 14 bit Specified Range - -40 to 125 °C Response time 8 63% >2 s Long Term Drift max. <0.03 °C/yr Sensitivity VDD=2.4V 11.6 mV/°C VDD=3.3V 16 mV/°C VDD=5.5V 26.7 mV/°C Table 2 Temperature sensor specification; values are target specs and not confirmed by measurements yet Figure 6 Tolerance of the temperature sensor in °C for the SHT30 and SHT31 1.3 Recommended Operating Condition The sensor shows best performance when operated within recommended normal temperature and humidity range of 5 – 60 °C and 20 – 80 %RH, respectively. Long term exposure to conditions outside normal range, especially at high humidity, may temporarily offset the RH signal (e.g.+3%RH after 60h at >80%RH). After returning into the normal temperature and humidity range the sensor will slowly come back to calibration state by itself. Prolonged exposure to extreme conditions may accelerate ageing. To ensure stable operation of the humidity sensor, the conditions described in the document “SHTxx Assembly of SMD Packages”, section “Storage and Handling Instructions” regarding exposure to volatile organic compounds have to be met. Please note as well that this does apply not only to transportation and manufacturing, but also to operation of the SHT3x-ARP. 2 Specifications 2.1 Electrical Specifications Parameter Symbol Condition Min Typ. Max Units Comments Supply voltage VDD 2.4 3.3 5.5 V Power-up/down level VPOR 2.2 2.28 2.35 V 8 Temperature response times strongly depends on the design-in of the sensor in the final application. Minimal response time can be achieved when the thermalized sensor at T1 is placed on a well conducting surface with temperature T2. ±0.0 ±0.5 ±1.0 ±1.5 ±2.0 -40 -20 0 20 40 60 80 100 120 Temperature (°C) SHT30/SHT31 maximal tolerance typical tolerance DT (°C) DT (°C) DT (°C) DT (°C) DT (°C) DT (°C) |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |