| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
MAX892LC/D bảng dữ liệu(PDF) 7 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX892LC/D bảng dữ liệu(HTML) 7 Page - Maxim Integrated Products |
|
7 / 8 page ![]() Thermal Shutdown The MAX891L/MAX892L feature thermal shutdown. The switch turns off when the junction temperature exceeds +135°C. Once the device cools by 10°C, the switch turns back on. If the fault short-circuit condition is not removed, the switch will cycle on and off, resulting in a pulsed output. Fault Indicator The MAX891L/MAX892L provide a fault output (FAULT). This open-drain output goes low when in current limit or when the die temperature exceeds +135°C. During start-up, FAULT is low until the switch is fully on and no over-current condition exists. A 100k Ω pull-up resistor from FAULT to IN provides a logic-control signal. __________Applications Information Input Capacitor To limit input voltage drop during momentary output short-circuit conditions, connect a capacitor from IN to GND. A 1µF ceramic capacitor is adequate for most applications; however, higher capacitor values further reduce voltage drop at the input. Output Capacitor Connect a 0.1µF capacitor from OUT to GND. One function of this capacitor is to prevent inductive para- sitics from pulling OUT negative during turn-off. Layout and Thermal-Dissipation Consideration To take full advantage of the switch-response time to output short-circuit conditions, it is very important to keep all traces as short as possible to reduce the effect of undesirable parasitic inductance. Place input and output capacitors as close as possible to the device (no more than 5mm). Under normal operating conditions, the package dissi- pates and channels heat away. Calculate maximum power as follows: P = I2LIM x RON where RON is the on-resistance of the switch. When the output is short circuited, voltage drop across the switch equals the input supply. Hence, the power dissipated across the switch increases, as does the die temperature. If the fault condition is not removed, the thermal-overload-protection circuitry turns the switch off until the die temperature falls by 10°C. A ground plane in contact with the device helps dissipate additional heat. ___________________Chip Information TRANSISTOR COUNT: 396 SUBSTRATE CONNECTED TO GND Current-Limited, High-Side P-Channel Switches with Thermal Shutdown _______________________________________________________________________________________ 7 MAX891L MAX892L SET RSET GND Figure 2. Setting the Current Limit |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |