| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
S35390A bảng dữ liệu(PDF) 36 Page - Seiko Instruments Inc |
|
|
|||||||||||||||||||||||||||||
S35390A bảng dữ liệu(HTML) 36 Page - Seiko Instruments Inc |
|
36 / 51 page ![]() FOR AUTOMOTIVE 105°C OPERATION 2-WIRE REAL-TIME CLOCK S-35390A H Series Rev.2.2_00 Seiko Instruments Inc. 36 Reset After Communication Interruption In case of communication interruption in the S-35390A H Series, for example, if the power supply voltage drops and only the master device is reset during communication, the S-35390A H Series does not perform the next operation because the internal circuit keeps the status prior to communication interruption. Since the S-35390A H Series does not have a reset pin, users usually reset its internal circuit by inputting a stop condition. However, if the SDA is outputting "L" (during output of acknowledgment signal or reading), the S-35390A H Series does not accept a stop condition from the master device. In this case, users are necessary to finish acknowledgment output or reading of the SDA. Figure 45 shows how to reset. First, input a start condition from the master device (the S-35390A H Series cannot detect a start condition because the SDA in the S-35390A H Series is outputting "L"). Next, input a clock pulse equivalent to 7-byte data access (63-clock) from the SCL. During this period, release the SDA line for the master device. By this procedure, SDA I/O before communication interruption is finished, and the SDA line in the S-35390A H Series is released. After that, inputting a stop condition resets the internal circuit and restores the regular communication. This reset procedure is recommended to be executed at initialization of the system after the master device's power supply voltage is raised. If this reset procedure is executed when the S-35390A H Series outputs an acknowledgment signal of a writing instruction, the writing operation may be performed at the corresponding register, so caution should be exercised. 1 2 62 63 89 Start condition Stop condition Clocks equivalent to 7-byte data access SCL "L" "L" or High-Z High-Z SDA (Master device output) SDA (S-35390A H Series output) SDA "L" or High-Z "L" Figure 45 How to Reset |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |