| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
AN4299 bảng dữ liệu(PDF) 13 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN4299 bảng dữ liệu(HTML) 13 Page - STMicroelectronics |
|
13 / 20 page ![]() DocID024663 Rev 2 13/20 AN4299 How to improve noise immunity 19 4.2 Active Shield The Active Shield is an electrode which wraps around the sensor. The goal is to minimize the parasitic capacitance between the sensor and the ground. To drive the shield electrode, a channel of a dedicated group with its own Cs can be used. Figure 6. Active Shield It is important to check the shied electrode waveform. Cs shield capacitance value and Rs shield serial resistor value must be adjusted in order to obtain the same signal shape as sensor electrode waveform (same amplitude, same response time). Figure 7 below shows the electrode sensor waveform in green and shield electrode waveform in yellow. Cs shield is adjusted to obtain approximately the same charge level at the end of the acquisition. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |