| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
UPD6604GS bảng dữ liệu(PDF) 24 Page - NEC |
|
|
|||||||||||||||||||||||||||||
UPD6604GS bảng dữ liệu(HTML) 24 Page - NEC |
|
24 / 64 page ![]() 24 µPD6604 Data Sheet U11281EJ3V0DS00 Table 5-3. Standby Mode Setup (HALT #b3b2b1b0B) and Release Conditions Operand Value of HALT Instruction Setting Mode Precondition for Setup Release Condition b3 b2 b1 b0 0000 STOP All KI/O pins are high-level output. High level is input to at least one of KI pins. 0 1 1 STOP All KI/O pins are high-level output. High level is input to at least one of KI pins. 1 1 0 STOPNote 1 The KI/O0 pin is high-level output. High level is input to at least one of KI pins. 1 Any of the STOP [The following condition is added in addition to the above.] combinations of — High level is input to at least one b2b1b0 above of S0 and S1 pinsNote 2. 0/1 1 0 1 HALT — When the timer’s down counter is 0 Notes 1. When setting HALT # ×110B, configure a key matrix by using the KI/O0 pin and the KI pin so that an internal reset takes effect at the time of program overrun. 2. At least one of the S0 and S1 pins (the pin used for canceling the standby) must be in INPUT mode. (The internal reset does not take effect even when both pins are in OUTPUT mode.) Cautions 1. The internal reset takes effect when the HALT instruction is executed with an operand value other than that above or when the precondition has not been satisfied when executing the HALT instruction. 2. If STOP mode is set when the timer’s down counter is not 0 (timer operating), the system is placed in STOP mode only after all the 10 bits of the timer’s down counter and the timer output permit flag are cleared to 0. 3. Write the NOP instruction as the first instruction after STOP mode is released. 5.3 Standby Mode Release Timing (1) STOP Mode Release Timing Figure 5-1. STOP Mode Cancelation by Release Condition Wait (36/fOSC) HALT mode OPERATING mode STOP mode Oscillation stopped Oscillation OPERATING mode Oscillation HALT instruction (STOP mode) Standby release signal Clock Caution When a release condition is established in the STOP mode, the device is released from the STOP mode and goes into a wait status. At this time, if the release condition is not held, the device goes into the STOP mode again after the wait time has elapsed. Therefore, when releasing the STOP mode, it is necessary to hold the release condition longer than the wait time. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |