| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
MSK4366 bảng dữ liệu(PDF) 4 Page - M.S. Kennedy Corporation |
|
|
|||||||||||||||||||||||||||||
MSK4366 bảng dữ liệu(HTML) 4 Page - M.S. Kennedy Corporation |
|
4 / 9 page ![]() Set Torque Proportional Value – Commands controller to receive torque proportional gain value. Send Contents: Command Tag followed by 16 bits of data [3 words]. Command Tag: 0x16 Data: 0x0000 – 0x7FFF Response Contents: Response Tag only [1 word]. Response Tag: 0x17 Description: Commands the controller to receive the torque proportional gain factor for programming the compensation values for the torque control digital error loop. Valid values are 0-32767. An input gain of 0 (zero) means that there will be no proportional gain at all, and that the torque error will go directly to the duty cycle control. A value of 32767 would equal the maximum possible gain. The value is stored in non- volatile memory and does not have to be re-introduced every time the device is powered up. Default Data Value: 0x0CCC 4 APPLICATION NOTES CONT'D APPLICATION NOTES CONT'D General Error Responses: 0xFFF0 = Invalid Data for Command Sent 0xFFF1 = Invalid Data Length for Command Sent 0xFFF2 = Unrecognized Command Tag 0xFFF3 = Overflow Error; Command not processed Get Status – Requests status of controller. Send Contents: Command Tag only [1 word]. Command Tag: 0x10 Response Contents: Response Tag followed by 8 bits of data[2words]. Response Tag: 0x11 Data: 0x01 – Running Mode 0x02 – Brake Mode 0x03 – Disable Mode Description: Will request status information from the controller. Status will indicate if control is in running mode, brake mode, or disable mode. Default Data Value: N/A Set Disable Mode – Commands controller to halt all PWM activity to the output bridge. Bridge is then inactive. Send Contents: Command Tag only [1 words]. Command Tag: 0x12 Response Contents: Response Tag only [1 word]. Response Tag: 0x13 Description: Commands the controller to disable the output bridge completely by shutting off all PWM modulation and all levels necessary to turn off all of the transistors. With the bridge now inactive, the motor can move freely. This does not reset command or PID history so motor will resume as last commanded when it is enabled. Default Data Value: Bridge is disabled by default. Set Enable Mode – Commands controller to enable all PWM activity to the output bridge. Bridge is then active. Send Contents: Command Tag only [1 words]. Command Tag: 0x14 Response Contents: Response Tag only [1 word]. Response Tag: 0x15 Description: Commands the controller to enable the output bridge. This will only have an effect if it is in disable mode or brake mode. The motor will resume normal control and move as previously commanded. Default Data Value: N/A MSK 4366 CAN COMMAND SET SUMMARY 8548-120 Rev. A 4/14 |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |