5 / 15 page ![]() AN2173 - APPLICATION NOTE 1 VIPer12-based Power Supply Features and Assembly 5/15 1.2 Assembly The initial PCBs and power supply assemblies were routed, built, and tested in the lab. An assembly fits into the case with the attached output wire cable that is connected from the flange to the end. If a Pollution Degree 1 rating is desired, the assembly should be in a sealed case, since the cable runs from the secondary (across the transformer) to the primary. Additionally, the transformer can be smaller if the case is sealed. If a sealed case is not used, then thicker insulation or triple-insulated wire may be required. Assembly EMI (EN5502, Class B) measurements are shown in Figure 4 on page 6. Figure 2. PCB Layout Figure 3. PCB Component Placement |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|