18 / 35 page ![]() AN1376 APPLICATION NOTE 18/35 As expected the circuit protects itself as well. The secondary peak current is obviously lower, due to the higher circuit impedance. Figure 18. 3V3 OUTPUT: SHORT C1 Like the previous output voltage the controller keeps under control the circuit preventing in all conditions the circuit from catastrophic failures. This happens even shorting the output by the active load. Figure 19. 12V OUTPUT: SHORT C19 Even the 12V output is well protected against shorts, either by a power switch or by the active load @85 VAC @265 VAC CH1: DRAIN VOLTAGE CH1: DRAIN VOLTAGE CH2: VC11 (Vaux) CH2: VC11 (Vaux) CH4: ISHORT CIRCUIT CH4: ISHORT CIRCUIT @85 VAC @265 VAC CH1: DRAIN VOLTAGE CH1: DRAIN VOLTAGE CH2: VC11 (Vaux) CH2: VC11 (Vaux) CH4: ISHORT CIRCUIT CH4: ISHORT CIRCUIT |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|