15 / 17 page ![]() AUTOMOTIVE 8XC196KB Parameter Typical (1) Minimum Maximum Units Resolution 512 1024 Level 9 10 Bits Absolute Error 0 g 6 LSBs Full Scale Error 025 g05 LSBs Zero Offset Error b 025 g05 LSBs Non-Linearity 15 g 25 0 g 4 LSBs Differential Non-Linearity l b 1 a 2 LSBs Channel-to-Channel Matching g 01 0 g 1 LSBs Repeatability g 025 LSBs(1) Temperature Coefficients Offset 0009 LSBC(1) Full Scale 0009 LSBC(1) Differential Non-Linearity 0009 LSBC(1) Off Isolation b 60 dB(1 2 4) Feedthrough b 60 dB(1 2) VCC Power Supply Rejection b 60 dB(1 2) Input Resistance 1K 5K X(1) DC Input Leakage 0 3 m A Sample Time (Prescaler onoff) 158 States (3) Input Capacitance 3 pF NOTES These values are expected for most parts at 25 C but are not tested or guaranteed An ‘‘LSB’’ as used here has a value of approximately 5 mV (See Automotive Handbook for AD glossary of terms 1 These values are not tested in production and are based on theoretical estimates andor laboratory test 2 DC to 100 KHz 3 One state e 125 ns 16 MHz 333 ns 6 MHz 4 Multiplexer Break-Before-Make Guaranteed 80C196KB FUNCTIONAL DEVIATIONS The 80C196KB has the following problems 1 The HSI unit has two errata one dealing with res- olution and the other with first entries into the FIFO The HSI resolution is 9 states instead of 8 states Events on the same line may be lost if they occur faster than once every 9 state times There is a mismatch between the 9 state time HSI resolution and the 8 state time timer This causes one time value to be unused every 9 timer counts Events may receive a time-tag one count later than expected because of this ‘‘skipped’’ time val- ue If the first two events into an empty FIFO (not including the Holding Register) occur in the same internal phase both are recorded with one time- tag Otherwise if the second event occurs within 9 states after the first its time-tag is one count later than the first’s If this is the ‘‘skipped’’ time value the second event’s time-tag is 2 counts lat- er than the first’s If the FIFO and Holding Register are empty the first event will transfer into the Holding Register after 8 state times leaving the FIFO empty again If the second event occurs after this time it will act as a new first event into an empty FIFO 2 If an AD conversion in progress is aborted by starting a new AD conversion results of the sec- ond conversion may be inaccurate 15 |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |