6 / 14 page ![]() Step-Up/Step-Down DC-DC Converter for 1-Cell Lithium-Ion Batteries Impala Linear Corporation 6 (408) 574-3939 www.impalalinear.com Jan 1999 ILC6360 1.1 At the start of one of the buck mode cycles, current starts to flow in the inductor. If the input voltage is greater than the output voltage, a normal PWM cycle will not stop the current build up in the inductor. Current continues to build up in the inductor and flows into the capacitor causing the capacitor voltage to build up as t2. At some point the PFM limit will be exceeded and the regulator will stop the normal PWM cycle and turn off. The energy stored in the inductor, 1/2*LI2, will be dissipated in the pass transistor. The current in the inductor will drop to zero and the “buck” cycle will start all over again. This mode of operation has similar efficiency as a linear regulator. The power dissipation and efficiency of the regu- lator is similar to a low dropout linear regulator : Power dissipiation, Pd = IOUT (VIN - VOUT) Efficiency, η = V OUT/VIN The advantage of this circuit is that there is no mode switching required by the user, it is automatic in the opera- tion of the circuit. For example, in the limit where VIN and VOUT are approximately equal, a mixture of PFM and PWM cycles will occur to maintain the output voltage in regula- tion. For the ILC6360 the buck mode of operation is limited to an input voltage 800mV higher than the out- put voltage or less. The output ripple will increase because of the larger cur- rent ripple associated with this mode of operation. The peak inductor current, Ipeak, is about double the average output current. A large output capacitor with low ESR will decrease the output ripple voltage. A smaller inductor will reduce the time needed to charge up the inductor to maxi- mum current. As a result, the output voltage ripple will decrease. A first order approximate equation for output rip- ple is as shown below : Vripple = ( K*L*IOUT2 ) / COUT where, L is the inductor value, COUT is the output capacitor value, IOUT is the regulator output current and K = 2.2. PWM Mode Operation The ILC6360 uses a PWM or Pulse Width Modulation tech- nique. The switches are constantly driven at typically 300kHz. The control circuitry varies the power being deliv- ered to the load by varying the on-time, or duty cycle, of the switch SW1 (see fig. 2). Since more on-time translates to higher current build-up in the inductor, the maximum duty cycle of the switch determines the maximum load current that the device can support. There are two key advantages of the PWM type controllers. First, because the controller automatically varies the duty cycle of the switch’s on-time in response to changing load conditions, the PWM controller will always have an opti- mized waveform for a steady-state load. This translates to very good efficiency at high currents and minimal ripple on the output. Ripple is caused by the constant charging and discharging of the output capacitor. The other key advantage of the PWM type controllers is that the radiated noise due to the switching transients will always occur at the (fixed) switching frequency harmonics. Many applications do not care much about switching noise, but certain types of applications, especially communication equipment, need to minimize the high frequency interfer- ence within their system as much as possible. Using a boost converter will cause higher frequency noise to be generated; using a PWM converter makes that noise high- ly predictable; thus easier to filter out. There are downsides of PWM approaches, especially at very low currents. Because the PWM technique relies on constant switching and varying duty cycle to match the load conditions, there is some point where the load current gets too small to be handled efficiently. An actual switch con- sumes some finite amount of current to switch on and off; at very low currents this can be of the same magnitude as the load current itself, driving switching efficiencies down to 50% and below. PFM Mode Operation The ILC6360 overcomes this limitation by automatically switching over to a PFM, or Pulse Frequency Modulation, technique at low currents. This technique conserves power loss by only switching the output if the current drain requires it. As shown in figure 3, the waveform actually skips pulses depending on the power needed by the out- put. This technique is also called “pulse skipping” because of this characteristic. V SET V OUT Switch Waveform Fig 3: PFM Waveform |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |