| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
ICS82C404 bảng dữ liệu(PDF) 6 Page - Integrated Circuit Systems |
|
|
|||||||||||||||||||||||||||||
ICS82C404 bảng dữ liệu(HTML) 6 Page - Integrated Circuit Systems |
|
6 / 13 page ![]() The serial data register is exactly 24 bits long, enough to accept the data being sent. The stop bit acts a load command that passes the contents of the Serial Data Register into the register indicated by the three address bits. If a stop bit is not received after the serial register is full, and more data is sent, all data in the register is ignored and an error issued. If correct data is received, then the unlocking mechanism rearms, all data in the serial data register is ignored, and an error is issued. Programming the ICS82C404 The ICS82C404 has a wide operating range, but it is recom- mended that it is operated within the following limits: 1 MHz < FREF < 60 MHz FREF=Input Reference Frequency 200 kHz < FREF/M < 5 MHz M=Reference divide 3 to 129 50 MHz < FVCO < 120 MHz FVCO=VCO output frequency FCLK < 120 MHz FCLK=output frequency The frequency of the programmable oscillator FVCO is deter- mined by the following fields: Field # of Bits Index (I) N counter value (N’) Mux (R) M counter value (M’) 4 7 3 7 Where the least significant bit is the last bit of M and the most significant bit is the first bit of 1. The equations used to determine the oscillator frequency are: N=N’ + 3 M=M’+2 FVCO=Prescale • N/M • FCLK where < M < 129 and 4 < N < 130 and prescale=2 or 4, as set in the control register The value of FVCO must remain between 50 MHz and 120 MHz. As a result, for output frequencies below 50 MHz, FVCO must be brought into range. To achieve this, an output divisor is selected by setting the values of the Mux Field (R) as follows: Output Divisor R Divisor 000 001 010 011 100 101 110 111 1 2 4 8 16 32 64 128 Unlike the ICD’s 82C404, the ICS82C404’s VCO does not require tuning to place it in certain ranges. The ICS82C404’s VCO will operate from 50 MHz to 120 MHz without adjusting the VCO gain. However, to maintain compatibility, the I bits are programmed as in the ICD2061A. These bits are dummy bits except for the following two cases: Index Field (I) I VCLK FVCO MCLK FVCO 1110 1111 Turn off VCLK Mux MCLK to VLCK 50-120 MHz 50-120 MHz When the index field is set to 1111, VCLK is turned off and both channels run from the same MCLK VCO. This is done in an effort to reduce jitter, which may increase when VCOs run at 2 n multiples of one another. If the two outputs must be multiples of one another, it is best to mux MCLK over to the output of the VCLK VCO, and to power-down the VCLK VCO. The multiplexed frequency will be divided down by the correct divisor (M) and output on VCLK. ICS82C404 6 |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |