| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
STC3115AIJT bảng dữ liệu(PDF) 11 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STC3115AIJT bảng dữ liệu(HTML) 11 Page - STMicroelectronics |
|
11 / 31 page ![]() DocID023755 Rev 4 11/31 STC3115 Functional description 31 6 Functional description 6.1 Battery monitoring functions 6.1.1 Operating modes The monitoring functions include the measurement of battery voltage, current, and temperature. A Coulomb counter is available to track the SOC when the battery is charging or discharging at a high rate. A sigma-delta A/D converter is used to measure the voltage, current, and temperature. The STC3115 can operate in two different modes with different power consumption (see Table 8. Mode selection is made by the VMODE bit in register 0 (refer to Table 13 for register 0 definition). In mixed mode, current is measured continuously (except for a conversion cycle every 4 s and every 16 s seconds for measuring voltage and temperature respectively). This provides the highest accuracy from the gas gauge. In voltage mode with no current sensing, a voltage conversion is made every 4 s and a temperature conversion every 16 s. This mode provides the lowest power consumption. It is possible to switch between the two operating modes to get the best accuracy during active periods, and to save power during standby periods while still keeping track of the SOC information. 6.1.2 Battery voltage monitoring Battery voltage is measured by using one conversion cycle of the A/D converter every 4 s. The conversion cycle takes 213 = 8192 clock cycles. Using the 32768 Hz internal clock, the conversion cycle time is 250 ms. The voltage range is 0 to 4.5 V and resolution is 2.20 mV. Accuracy of the voltage measurement is ±0.5% over the temperature range. This allows accurate SOC information from the battery open-circuit voltage. The result is stored in the REG_VOLTAGE register (see Table 12). Table 8. STC3115 operating modes VMODE Description 0 Mixed mode, Coulomb counter is active, voltage gas gauge runs in parallel 1 Voltage gas gauge with power saving Coulomb counter is not used. No current sensing. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |