3 / 6 page ![]() All specifications are for 20 to 30 ˚C and for 1 year unless otherwise noted. All specifications are relative to calibration standards and require a 15 minute warm-up period. Specifications do not include transducer error. Input Characteristics Number of channels......................................... 8 Input frequency ranges (software selectable) and corresponding output voltage range1 Minimum recommended input frequency based on output filter setting Minimum input pulse width............................. 1.5 µs (5 V pulse train at 128 kHz) Input signal amplitude range ........................... (1,000 VDC/680 Vrms with the TBX-1316) ±50 mV minimum to ±250 V maximnum Input coupling................................................... DC (AC with SCXI-1305 or TBX-1329) Maximum working voltage2,3........................... Each input should remain within 250 Vrms of chassis ground or any other input terminal (signal + common mode voltage) Overvoltage protection3 ................................... 250 Vrms, powered on or off Inputs protected ............................................... CH<0..7> Input impedance Powered on................................................ 50 G (-0.5 to 4.5 V) Overload..................................................... 50 k (-250 to -0.5 V and 4.5 to 250 V) Powered off ...................................................... 50 k Input bias current ............................................. 500 pA maximum (0 to 50˚) Threshold (software programmable) Range......................................................... -0.5 to 4.98 V (-50 to 250 V with SCXI-1327 high-voltage terminal block) Resolution.................................................. 8 bits Hysteresis .................................................. 0 to 4.98 V (0 to 250 V with SCXI-1327 high- voltage attenuator terminal block) Transfer Characteristics4 Output Characteristics Output impedance Multiplexed output mode.......................... 100 Parallel output mode ................................. 330 Output short circuit protection......................... Indefinite duration Outputs protected ............................................ MCH<0..7> Filters (software programmable) Type .................................................................. 4-pole, active lowpass Power-Up and Reset States Bandwidth and Response Time Stability Recommended warm-up time.......................... 15 minutes Temperature drift (0 to 20 ˚C; 30 to 50 ˚C)7 In ppm/˚C ................................................... ±9 ppm of reading/˚C ±6.4 ppm In Hz/˚C of range/˚C Calibration cycle............................................... 1 year Physical Dimensions....................................................... 3.0 by 17.2 by 20.3 cm (1.2 by 6.8 by 8.0 in.) I/O connectors .................................................. 50-pin male ribbon cable rear connector 32-pin male DIN C front I/O connector Environment Operating temperature..................................... 0 to 50 ˚C Storage temperature ........................................ -20 to 70 ˚C Relative humidity ............................................. 5 to 90% noncondensing Certifications and Compliances European Compliance EMC ................................................................. EN 61326 Group I Class A, 10m, Table 1 Immunity Safety .............................................................. EN 61010-1 North American Compliance EMC ................................................................. FCC Part 15 Class A using CISPR Safety ............................................................... UL Listed to UL 3111-1 CAN/CSA C22.2 No. 1010.1 1 V rms refers to a sinusoidal waveform; V refers to DC or AC peak 2 As specified by IEC-1010 for Pollution Degree 2 and Installation Category II 3 Voltage is limited to 30 V rms (42.4 V) if using the SCXI-1305 terminal block 4 Accuracy is based on the combination of all errors, including the effects of temperature drift over the range 20 to 30 ˚C 5 Includes effects of AT-MIO-16E-2 with 1 or 2 m SCXI cable assembly 6 Includes effects of AT-MIO-16XE-10 with 1 or 2 m SCXI cable assembly 7 See Transfer Characteristics for temperature drift over the range 20 to 30 ˚C For a definition of specific terms, please visit ni.com/glossary 308 National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni.com • ni.com SCXI 8-Channel Isolated Frequency Input Module Specifications Input Frequency Ranges Output Voltage Range 250 Hz, 500 Hz, 1 kHz, 2 kHz 0 to 5 V 4 kHz, 8 kHz, 16 kHz, 32 kHz 64 kHz, 128 kHz Input Frequency Ranges Temperature Drift Percent of Reading/˚C + Hz/˚C 250 Hz 0.0009% ±0.002 Hz 500 Hz 0.0009% ±0.003 Hz 1 kHz 0.0009% ±0.006 Hz 2 kHz 0.0009% ±0.013 Hz 4 kHz 0.0009% ±0.026 Hz 8 kHz 0.0009% ±0.051 Hz 16 kHz 0.0009% ±0.102 Hz 32 kHz 0.0009% ±0.204 Hz 64 kHz 0.0009% ±0.407 Hz 128 kHz 0.0009% ±0.814 Hz Output Filter Bandwidth Setting Minimum Input Frequency 1 Hz 15 Hz 40 Hz 600 Hz 320 Hz 5 kHz 1000 Hz 15 kHz Bandwidth Step Response Settling Time (ms) Full Scale Input Step (-3 dB) (Hz) to ±1% to ±0.1% to ±0.024% 1.0 800.0 1,530.0 5,300.0 40.0 30.0 55.0 180.0 320.0 3.2 7.0 30.0 1000.0 0.8 1.0 1.2 Function Power-Up State Software Reset State Hardware Reset State Scanning mode* Parallel Retains last setting Parallel prior to software reset DAQ device DIFF Retains last setting DIFF Connection mode* prior to software reset Input frequency range 0 to128 kHz 0 to128 kHz 0 to128 kHz Filter setting 1 Hz 1 Hz 1 Hz Threshold level -0.5 V -0.5 V Retains last setting prior to software reset Hysteresis level 0 V 0 V Retains last setting prior to software reset *Output modes Input Noise (Hz) Frequency Percent of Reading + Hz* (DC to 255 kHz) Ranges 24 hours 90 days 1 year peak rms 250 Hz 0.0150% ± 0.011 Hz 0.0217% ± 0.018 Hz 0.0418% ± 0.039 Hz 0.05 0.008 500 Hz 0.0150% ± 0.023 Hz 0.0217% ± 0.036 Hz 0.0418% ± 0.077 Hz 0.10 0.015 1 kHz 0.0150% ± 0.045 Hz 0.0217% ± 0.073 Hz 0.0418% ± 0.154 Hz 0.20 0.030 2 kHz 0.0150% ± 0.091 Hz 0.0217% ± 0.145 Hz 0.0418% ± 0.308 Hz 0.40 0.061 4 kHz 0.0150% ± 0.181 Hz 0.0217% ± 0.290 Hz 0.0418% ± 0.616 Hz 0.8 0.121 8 kHz 0.0150% ± 0.363 Hz 0.0217% ± 0.580 Hz 0.0418% ± 1.231 Hz 1.60 0.242 16 kHz 0.0150% ± 0.726 Hz 0.0217% ± 1.160 Hz 0.0418% ± 2.462 Hz 3.20 0.485 32 kHz 0.0150% ± 1.451 Hz 0.0217% ± 2.319 Hz 0.0418% ± 4.924 Hz 6.40 0.970 64 kHz 0.0150% ± 2.902 Hz 0.0217% ± 4.638 Hz 0.0418% ± 9.848 Hz 12.80 1.939 128 kHz 0.0150% ± 5.803 Hz 0.0217% ± 9.276 Hz 0.0418% ± 16.696 Hz 25.60 3.879 *Accuracy Scan Interval (Per Channel, Any Frequency Range and Filter Bandwidth) Module Settle to ±0.012%5 Settle to ±0.006%6 Settle to ±0.0015%6 SCXI-1126 3 µs 10 µs 20 µs |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |