22 / 41 page ![]() TCS3404, TCS3414 DIGITAL COLOR SENSORS TAOS137A − APRIL 2011 21 The LUMENOLOGY r Company r r Copyright E 2011, TAOS Inc. www.taosinc.com APPLICATION INFORMATION: SOFTWARE Basic Operation After applying VDD, the device will initially be in the power−down state. To operate the device, issue a command to access the control register followed by the data value 03h to the control register to set ADC_EN and POWER to power up the device. At this point, all four ADC channels will begin a conversion at the default integration time of 12 ms. After 12 ms, the conversion results will be available in ADC Channel Data Registers (10h through 17h). The following pseudo code illustrates a procedure for reading the TCS3404/14 device using Word and Byte transactions: // Read ADC Channels Using Read Word Protocol − RECOMMENDED Address = 0x39 Command = 0x80 PowerUp = 0x03 //Power Up and Enable ADC //Wait for integration conversion //Address the Ch1 lower data register and configure for Read Word Command = 0xB0 //Set Command bit and Word transaction //Reads two bytes from sequential registers 10h and 11h //Results are returned in DataLow and DataHigh variables ReadWord (Address, Command, DataLow, DataHigh) Channel1 = 256 * DataHigh + DataLow //Address the Ch2 lower data register and configure for Read Word Command = 0xB2 //Set Command bit and Word transaction //Reads two bytes from sequential registers 12h and 13h //Results are returned in DataLow and DataHigh variables ReadWord (Address, Command, DataLow, DataHigh) Channel2 = 256 * DataHigh + DataLow //Shift DataHigh to upper byte //Address the Ch3 lower data register and configure for Read Word Command = 0xB4 //Set Command bit and Word transaction //Reads two bytes from sequential registers 14h and 15h //Results are returned in DataLow and DataHigh variables ReadWord (Address, Command, DataLow, DataHigh) Channel3 = 256 * DataHigh + DataLow //Address the Ch4 lower data register and configure for Read Word Command = 0xB8 //Set Command bit and Word transaction //Reads two bytes from sequential registers 16h and 17h //Results are returned in DataLow and DataHigh variables ReadWord (Address, Command, DataLow, DataHigh) Channel4 = 256 * DataHigh + DataLow //Shift DataHigh to upper byte |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |