5 / 18 page ![]() AS5035 – 64 PPR INCREMENTAL MAGNETIC ROTARY ENCODER Revision 1.5 www.austriamicrosystems.com Page 4 of 17 5.5 MagInc and MagDec Indicators These two pins are open-drain outputs with a maximum driving capability of 2mA @ 3.0V and 4mA @ 4.5V. MagINC, (Magnitude Increase) turns on, when the magnet is pushed towards the IC, thus when the magnetic field strength is increasing. MagDEC, (Magnitude Decrease) turns on, when the magnet is pulled away from the IC, thus when the magnetic field strength is decreasing. If both outputs are low, they indicate that the magnetic field out of the allowed range: MagINC MagDEC Description off off No distance change. Magnetic Input Field OK off on Distance increase (Magnet pulled away from IC) on off Distance decrease (Magnet pushed towards IC) on on Magnetic Input Field invalid – out of range: either too large (magnet too close) or too small (missing magnet or magnet too far away) Table 2: Magnetic field strength diagnostic outputs off = open-drain output transistor is off. Using a pull-up resistor, the output is high on = open-drain output transistor is on. Using a pull-up resistor, the output is low Both outputs MagInc and MagDec may be tied together, using one common pull-up resistor. In this case, the output will be high only when the magnetic field is in range. It will be low when either the magnet is moving in Z-axis or when the magnetic field is out of range. 6 Incremental Outputs 6.1 A, B and Index The phase shift between channel A and B indicates the direction of the magnet movement. Channel A leads channel B at a clockwise rotation of the magnet (top view, magnet placed above or below the device) with 90 electrical degrees. Channel B leads channel A at a counter-clockwise rotation. The Index pulse has a width of 1LSB = 1.4° 6.2 Hysteresis To avoid flickering of the incremental outputs at a stationary mechanical position, a hysteresis of 0.7° is introduced. When the direction of rotation is reversed, the incremental outputs will not change state unless the movement in the opposite direction is larger than the hysteresis. This leads to the effect that the A,B and Index pulse positions will be shifted by 0.7° when the rotational direction is reversed. This shift is cancelled again with the next reversal of direction so that the A,B and Index pulses appear always at the same position for a given rotational direction no matter how often the rotational direction is reversed (see Figure 5). . A B Index= 1.40625° Index Mechanical Zero Position Rotation Direction Change CSn t Incremental outputs valid Hysteresis =0.7° Mechanical Zero Position power-up 1.40625° =90e° 5.625° =360e° Figure 5: Incremental quadrature outputs |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |