Back Button LM3444MM Datasheet HTML 9Page - Texas Instruments LM3444MM Datasheet HTML 10Page - Texas Instruments LM3444MM Datasheet HTML 11Page - Texas Instruments LM3444MM Datasheet HTML 12Page - Texas Instruments LM3444MM Datasheet HTML 13Page - Texas Instruments LM3444MM Datasheet HTML 14Page - Texas Instruments LM3444MM Datasheet HTML 15Page - Texas Instruments LM3444MM Datasheet HTML 16Page - Texas Instruments LM3444MM Datasheet HTML 17Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 30 page
background image
1
K
VLED
VBUCK
u
¸
¹
·
¨
©
§
fSW =
1
tOFF
VLED
= K u D
VBUCK
D
tON
fSW =
, and
1 - D
tOFF
fSW =
1
tOFF + tON
fSW =
D =
tON
tON + tOFF
=
VLED
VBUCK
'¶ =
tOFF
tON + tOFF
LM3444
www.ti.com
SNVS682C – NOVEMBER 2010 – REVISED MAY 2013
Common equations for determining duty cycle and switching frequency in any buck converter:
(8)
Therefore:
(9)
With efficiency of the buck converter in mind:
(10)
Substitute equations and rearrange:
(11)
Off-time, and switching frequency can now be calculated using the equations above.
SETTING THE SWITCHING FREQUENCY
Selecting the switching frequency for nominal operating conditions is based on tradeoffs between efficiency
(better at low frequency) and solution size/cost (smaller at high frequency).
The input voltage to the buck converter (VBUCK) changes with both line variations and over the course of each
half-cycle of the input line voltage. The voltage across the LED string will, however, remain constant, and
therefore the off-time remains constant.
The on-time, and therefore the switching frequency, will vary as the VBUCK voltage changes with line voltage. A
good design practice is to choose a desired nominal switching frequency knowing that the switching frequency
will decrease as the line voltage drops and increase as the line voltage increases (Figure 17).
Copyright © 2010–2013, Texas Instruments Incorporated
Submit Documentation Feedback
13
Product Folder Links: LM3444



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com