17 / 40 page ![]() 17 Am29LV116B PREL I M I N AR Y quence should be reinitiated once the device has reset to reading array data, to ensure data integrity. Programming is allowed in any sequence and across sector boundaries. A bit cannot be programmed from a “0” back to a “1”. Attempting to do so may halt the operation and set DQ5 to “1,” or cause the Data# Polling algorithm to indicate the operation was suc- cessful. However, a succeeding read will show that the data is still “0”. Only erase operations can convert a “0” to a “1”. Unlock Bypass Command Sequence The unlock bypass feature allows the system to pro- gram bytes to the device faster than using the standard program command sequence. The unlock bypass com- mand sequence is initiated by first writing two unlock cycles. This is followed by a third write cycle containing the unlock bypass command, 20h. The device then en- ters the unlock bypass mode. A two-cycle unlock by- pass program command sequence is all that is required to program in this mode. The first cycle in this sequence contains the unlock bypass program com- mand, A0h; the second cycle contains the program ad- dress and data. Additional data is programmed in the same manner. This mode dispenses with the initial two unlock cycles required in the standard program com- mand sequence, resulting in faster total programming time. Table 9 shows the requirements for the command sequence. During the unlock bypass mode, only the Unlock By- pass Program and Unlock Bypass Reset commands are valid. To exit the unlock bypass mode, the system must issue the two-cycle unlock bypass reset com- mand sequence. The first cycle must contain the data 90h; the second cycle the data 00h. Addresses are don’t cares for both cycles. The device then returns to reading array data. Figure 3 illustrates the algorithm for the program oper- ation. See the Erase/Program Operations table in “AC Characteristics” for parameters, and to Figure 15 for timing diagrams Note: See Table 9 for program command sequence. Figure 3. Program Operation START Write Program Command Sequence Data Poll from System Verify Data? No Yes Last Address? No Yes Programming Completed Increment Address Embedded Program algorithm in progress 21359C-6 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |