12 / 20 page ![]() HR2000 — FLUORESCENT LAMP HB DRIVER WITH PFC HR2000 Rev. 1.0 www.MonolithicPower.com 12 2/20/2013 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2013 MPS. All Rights Reserved. PIN FUNCTIONS Pin # Name Description 1 VO PFC output control pin. Connect a resistor from this pin to the PFC output to set the PFC output voltage. Connect a capacitor (or a R-C-C network) from this pin to GND for the compensation of the PFC regulation loop. 2 ZCD PFC inductor zero current detection pin. 3 OVC PFC over voltage/current protection pin. 4 CT Frequency setting capacitor pin. Connect a capacitor from this pin to GND to set the frequency. 5 FC Frequency control pin. It is voltage controlled oscillator (VCO) pin for controlling half bridge frequency. 6 CP/EOL Preheat/ignition timing pin and EOL detector. A capacitor from this pin to GND sets the preheat time and ignition time. Before half-bridge works, it is discharged internally to GND. In the preheat state and ignition state, a triangle waveform is generated on this pin and used as a timer. The voltage of the blocking capacitor is sensed to this pin to indicate the EOL condition. After preheat and ignition state, the voltage at this pin is internally discharged to the middle of the EOL window comparator’s reference, and then the lamp’s EOL information is under monitoring. If EOL condition is confirmed, an internal current source charges the Pre/FT pin’s capacitor. 7 REF Internal reference current setting resistor pin. Connect a resistor from this pin to GND to set the frequency. 8 Pre/FT In the preheat state, this pin outputs a high level voltage to drive the external preheating MOSFET. After this period, it is discharged to Vfault (reset2). Then it is used as a fault timer to stop IC at fault condition. At fault condition, an internal current source charges up this pin, and when its voltage hits the fault reference threshold, IC latches up. Connect a capacitor on this pin to set the fault timer. 9 BST Bootstrap voltage supply for half bridge level shifter. Connect a capacitor (usually 10nF to 100nF) between this pin and SW pin. 10 UG Half bridge up side MOSFET driver. 11 SW Half bridge floating middle point. 12 CS Half bridge current sensor. 13 LG Half bridge low side MOSFET driver. 14 VCC Supply voltage of the IC. 15 GND Ground 16 GATE PFC GATE driver pin. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |