| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
AD7738 bảng dữ liệu(PDF) 22 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7738 bảng dữ liệu(HTML) 22 Page - Analog Devices |
|
22 / 28 page ![]() REV. 0 –22– AD7738 Continuous Conversion Mode When the Mode register is being written, the ADC Status Byte is cleared and the RDY pin goes high regardless of its previous state. When the continuous conversion command is written to the Mode register, the ADC starts conversion on the channel selected by the address of the Mode register. After the conversion is complete, the relevant Channel Data register and Channel Status register are updated, the relevant RDY bit in the ADC Status register is set, and the AD7738 continues converting on the next enabled channel. The AD7738 will cycle through all enabled channels until put into another mode or reset. The cycle period will be the sum of all enabled channels’ conversion times, set by corresponding Channel Conversion Time registers. The RDY bit is reset when the relevant Channel Data register is being read. The behavior of the RDY pin depends on the RDYFN bit in the I/O Port register. When RDYFN bit is 0, the RDY pin goes low when any channel has unread data. When this bit is set to 1 the RDY pin will only go low if all enabled channels have unread data. If an ADC conversion result has not been read before a new ADC conversion is completed, then the new result will overwrite the previous one. The relevant RDY bit goes low and the RDY pin goes high for at least 163 MCLK cycles (~26.5 µs), indicating when the Data register is updated and the previous conversion data is lost. If the Data register is being read as an ADC conversion completes, then the Data Register will not be updated with the new result (to avoid data corruption) and the new conversion data is lost. Figure 9 shows the digital interface signals sequence for the Continuous Conversion mode with Channels 0 and 1 enabled and the RDYFN bit set to 0. The RDY pin goes low and the Data Register is read after each conversion. Figure 10 shows a similar sequence, but with the RDYFN bit set to 1. The RDY pin goes low and the Data register is read after all conversions are completed. Figure 11 shows the RDY pin when no data are read from the AD7738. CH0 CONVERSION CH1 CONVERSION CH0 CONVERSION CH1 CONVERSION CH0 CONVERSION START CONTINUOUS CONVERSION SERIAL INTERFACE READ DATA CH0 READ DATA CH1 READ DATA CH0 READ DATA CH1 RDY Figure 9. Continuous Conversion, CH0 and CH1, RDYFN = 0 RDY CH0 CONVERSION CH1 CONVERSION CH0 CONVERSION CH1 CONVERSION CH0 CONVERSION READ DATA CH0 READ DATA CH1 START CONTINUOUS CONVERSION SERIAL INTERFACE READ DATA CH0 READ DATA CH1 Figure 10. Continuous Conversion, CH0 and CH1, RDYFN = 1 SERIAL INTERFACE START CONTINUOUS CONVERSION RDY CH0 CONVERSION CH1 CONVERSION CH0 CONVERSION CH1 CONVERSION CH0 CONVERSION Figure 11. Continuous Conversion, CH0 and CH1, No Data Read |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |