2 / 8 page ![]() 248 Power PCB Relay G8PT ■ Coil Data Note: 1. The rated current and coil resistance are measured at a coil temperature of 23 °C with tolerances of ±10%. 2. The operating characteristics are measured at a coil temperature of 23 °C. 3. The “Maximum Voltage is the maximum voltage that can be applied to the relay coil. ■ Characteristics Note: 1. Data shown are of initial value. Operate and release times excluding bounce. 2. Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter. 3. Please vent sealed relays after processing in order to achieve rated electrical service life, by removing the vent nib. ■ Characteristic Data Rated voltage (VDC) Rated current (mA) Coil resistance ( Ω) Pick-up voltage Dropout voltage Maximum voltage Power consumption (mW) % of rated voltage 5 185 27 75% max. 10% min. 120% max. Approx. 900 993 97 12 77 155 24 36 660 48 19 2,480 110 9 12,400 Contact resistance 100 m Ω max. (measured with 5 VDC, 1 A, voltage drop method) Operate time 15 ms. max. (-BG: 20 ms max.) Release time 10 ms. max. Insulation resistance (See note 2) 100 M Ω min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 minute (between coil and contacts), (-BG: 4,000 VAC) 1,500 VAC, 50/60 Hz for 1 minute (between contacts of the same polarity) Impulse surge withstand 6,000 V between coil and contacts (1.2/50 μs) Vibration resistance Destruction 10 to 55 Hz, 1.65 mm double amplitude for 2 hours (-BG: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours) Malfunction 10 to 55 Hz, 1.65 mm double amplitude for 5 minutes Shock resistance Destruction 1,000 m/s2 (approx. 100 G) Malfunction 100 m/s2 (approx. 10 G) Ambient operating temperature -55 ° to 105°C, cold coil condition (with no icing) -55 ° to 85°C, hot coil condition (hot start) (with no icing) Ambient operating humidity 5% to 85% RH Service life Mechanical 10 million operations minimum at 18,000 ops/hour. (-BG: 5 million operations min.) Electrical 100,000 operations approx. at 360 ops/hr. (-BG: 40,000 operations min.) Weight Approx. 24 g to 31 g AC resistive load (-BG type) Maximum switching capacity SPST-NO Rated operating voltage (V) SPDT Rated operating voltage (V) |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |