28 / 80 page ![]() ADAS1000/ADAS1000-1/ADAS1000-2 Data Sheet Rev. A | Page 28 of 80 ECG INPUTS—ELECTRODES/LEADS The ADAS1000/ADAS1000-1/ADAS1000-2 ECG product consists of 5 ECG inputs and a reference drive, RLD (right leg drive). In a typical 5-lead/vector application, four of the ECG inputs (ECG3_RA, ECG1_LA, ECG2_LL, ECG4_V1) would be used in addition to the RLD path. This leaves one spare ECG path (which could be used for other purposes, such as calibration or temperature measurement). Both V1 and V2 input channels can be used for alternative measurements if desired. When used in this way, the negative terminal of the input stage can be switched to the fixed internal VCM_REF = 1.3 V; see details in Table 48. In a 5-lead system, the ADAS1000/ADAS1000-1/ADAS1000-2 can provide Lead I, Lead II, and Lead III data or electrode data directly via the serial interface at all frame rates. The other ECG leads can be calculated by the user’s software from either the lead data or the electrode data provided by the ADAS1000/ ADAS1000-1/ADAS1000-2. Note that in 128 kHz data rate, lead data is only available when configured in analog lead mode as shown in Figure 57. Digital lead mode is not available for this data rate. A 12-lead (10-electrode) system can be achieved using one ADAS1000 or ADAS1000-1 device ganged together with one ADAS1000-2 slave device as described in the Gang Mode Operation section. Here, 9 ECG electrodes and one RLD electrode achieve the 10 electrode system, again leaving one spare ECG channel that could be used for alternate purposes as suggested previously. In such a system, having nine dedicated electrodes benefits the user by delivering lead information based on electrode measurements and calculations rather than deriving leads from other lead measurements. Table 10 outlines the calculation of the leads (vector) from the individual electrode measurements. Table 10. Lead Composition1 Lead Name Composition Equivalent ADAS1000 or ADAS1000-1 I LA – RA II LL – RA III LL – LA aVR2 RA – 0.5 × (LA + LL) −0.5 × (I + II) aVL2 LA – 0.5 × (LL + RA) 0.5 × (I − III) aVF2 LL – 0.5 × (LA + RA) 0.5 × (II + III) V1’ V1 – 0.333 × (LA + RA + LL) V2’ V2 – 0.333 × (LA + RA + LL) 12 Leads Achieved by Adding ADAS1000-2 Slave V3’ V3 – 0.333 × (LA + RA + LL) V4’ V4 – 0.333 × (LA + RA + LL) V5’ V5 – 0.333 × (LA + RA + LL) V6’ V6 – 0.333 × (LA + RA + LL) 1 These lead compositions apply when the master ADAS1000 device is configured into lead mode (analog lead mode or digital lead mode) with VCM = WCT = (RA + LA + LL)/3. When configured for 12-lead operation with a master and slave device, the VCM signal derived on the master device (CM_OUT) is applied to the CM_IN of the slave device. For correct operation of the slave device, the device must be configured in electrode mode (see the FRMCTL register in Table 35). 2 These augmented leads are not calculated within the ADAS1000, but can be derived in the host DSP/microcontroller/FPGA. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |