| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
SC210KSIT bảng dữ liệu(PDF) 11 Page - SEC Electronics Inc. |
|
|
|||||||||||||||||||||||||||||
SC210KSIT bảng dữ liệu(HTML) 11 Page - SEC Electronics Inc. |
|
11 / 13 page ![]() SC210KSIT 120 kHz Bandwidth, High Voltage Isolation Current Sensor with Integrated Overcurrent Detection 11/13 Setting Overcurrent Fault Switchpoint The VOC needed for setting the overcurrent fault switchpoint can be calculated as follows: VOC = 1.17 × Sens × | IOC | , where VOC is in mV, Sens in mV/A, and IOC (overcurrent fault switchpoint) in A. | Ioc | is the overcurrent fault switchpoint for a bidirectional (AC) current, which means a bi-directional sensor will have two symmetrical overcurrent fault switchpoints, +IOC and –IOC . See the following graph for IOC and VOC ranges: Example:For SC210KSIT, if required overcurrent fault switchpoint is 20 A, and VCC = 5 V, then the required VOC can be calculated as follows: VOC = 1.17 × Sens × IOC = 1.17 × 85 × 15 = 1492 (mV) Overcurrent Fault Operation The primary concern with high-speed fault detection is that noise may cause false tripping. Various applications have or need to be able to ignore certain faults that are due to switching noise or other parasitic phenomena, which are application dependant. The problem with simply trying to filter out this noise in the main signal path is that in high-speed applications, with asymmetric noise, the act of filtering introduces an error into the measurement. To get around this issue, and allow the user to prevent the fault signal from being latched by noise, a circuit was designed to slew the FAULT pin voltage based on the value of the capacitor from that pin to ground. Once the voltage on the pin falls below 2 V, as established by an internal reference, the fault output is latched and pulled to ground quickly with an internal N-channel MOSFET. Fault Walk-through The following walk-through references various sections and attributes in the figure below. This figure shows different fault set/reset scenarios and how they relate to the voltages on the FAULT pin, FAULT_EN pin, and the internal Overcurrent (OC) Fault node, which is invisible to the customer. 1. Because the device is enabled (FAULT_EN is high for a minimum period of time, the Fault Enable Delay, tFED , 15 μs typical) and there is an OC fault condition, the device FAULTpin |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |