Back Button ADE7753ARSZ Datasheet HTML 30Page - Analog Devices ADE7753ARSZ Datasheet HTML 31Page - Analog Devices ADE7753ARSZ Datasheet HTML 32Page - Analog Devices ADE7753ARSZ Datasheet HTML 33Page - Analog Devices ADE7753ARSZ Datasheet HTML 34Page - Analog Devices ADE7753ARSZ Datasheet HTML 35Page - Analog Devices ADE7753ARSZ Datasheet HTML 36Page - Analog Devices ADE7753ARSZ Datasheet HTML 37Page - Analog Devices ADE7753ARSZ Datasheet HTML 38Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 34 / 60 page
background image
ADE7753
Rev. C | Page 34 of 60
90°. The resulting waveform is called the instantaneous reactive
power signal. Equation 25 gives an expression for the instanta-
neous reactive power signal in an ac system when the phase of
the current channel is shifted by +90°.
The average reactive power over an integral number of lines (n)
is given in Equation 26.
v(t) =
)
sin(
2
θ
+
ωt
V
(23)
=
=
nT
VI
dt
t
Rp
nT
RP
0
)
sin(
)
(
1
θ
(26)
i(t) =
)
sin(
2
t
I
ω
π
+
ω
=
2
sin
2
)
(
t
I
t
i
(24)
where:
T is the line cycle period.
RP is referred to as the reactive power.
Note that the reactive power is equal to the dc component of the
instantaneous reactive power signal Rp(t) in Equation 25. This
is the relationship used to calculate reactive power in the
ADE7753. The instantaneous reactive power signal Rp(t) is
generated by multiplying Channel 1 and Channel 2. In this case,
the phase of Channel 1 is shifted by +90°. The dc component of
the instantaneous reactive power signal is then extracted by a
low-pass filter in order to obtain the reactive power informa-
tion. Figure 71 shows the signal processing in the reactive
power calculation in the ADE7753.
where:
θ is the phase difference between the voltage and current
channel.
V is the rms voltage.
I is the rms current.
Rp(t) = v(t) × i’(t)
(25)
Rp(t) = VI sin (θ) + VI sin(2ωt + θ)
ZERO-CROSSING
DETECTION
MULTIPLIER
+
+
LVARENERGY [23:0]
ACCUMULATE REACTIVE
ENERGY IN INTERNAL
REGISTER AND UPDATE
THE LVARENERGY REGISTER
AT THE END OF LINECYC HALF
LINE CYCLES
INSTANTANEOUS REACTIVE
POWER SIGNAL (Rp(t))
23
0
49
0
02875-0-070
LPF1
FROM
CHANNEL 2
ADC
LINECYC [15:0]
LPF2
CALIBRATION
CONTROL
π
2
V
I
90 DEGREE
PHASE SHIFT
Figure 71. Reactive Power Signal Processing



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com