4 / 28 page ![]() Wide variety of control and maintenance functions using DeviceNet. 4 5 6 DeviceNet Configurator DRT2-ID16(-1) DRT2-OD16(-1) DRT2-ID08(-1) DRT2-OD08(-1) DRT2-MD16(-1) Settings and monitoring for startup Settings and monitoring for maintenance DRT2-ROS16 DRT2-ID16S(-1) DRT2-MD16S(-1) DRT2-AD04/DRT2-AD04H DRT2-DA02 DRT2-TS04T DRT2-TS04P DRT2-ID08C(-1) DRT2-OD08C(-1) DRT2-HD16C(-1) I/O Control and Maintenance Sensor Input and Maintenance Monitor Control and Maintenance Analog Control and Maintenance E5ZN-DRT 3G3MV-PDRT2 (for 3G3MV Series) 3G3RV-PDRT2 (for 3G3RV Series) DRT2-ID32ML(-1) DRT2-OD32ML(-1) DRT2-MD32ML(-1) DRT2-ID16ML(-1) DRT2-OD16ML(-1) DRT2-ID16MLX(-1) DRT2-OD16MLX(-1) DRT2-ID16TA(-1) DRT2-OD16TA(-1) DRT2-MD16TA(-1) DRT2-ID04CL(-1) DRT2-OD04CL(-1) DRT2-ID08CL(-1) DRT2-OD08CL(-1) DRT2-MD16CL(-1) DRT2-HD16CL(-1) DRT2-WD16CL(-1) Monitor network devices using a DeviceNet Configurator. PLC CS/CJ-series DeviceNet Unit DRT2-ID32SL(H)(-1) DRT2-OD32SL(H)(-1) DRT2-MD32SL(H)(-1) DRT2-ID32B(-1) DRT2-OD32B(-1) DRT2-MD32B(-1) DRT2-ID32BV(-1) DRT2-OD32BV(-1) DRT2-MD32BV(-1) Board Terminals with MIL Connectors Remote I/O Terminals with Screw-less Clamps e-CON Connector Terminals Analog I/O Terminals Temperature Input Terminals DeviceNet Communications Unit for E5ZN Digital Temperature Controllers DeviceNet Communications Units/Cards for Inverters Remote I/O Terminals with Transistors Remote I/O Terminal with Relay Outputs Environment-resistive Terminals with Transistors (with detection functions) Remote I/O Terminals with 3-tier Terminal Blocks MIL Connector Terminals Environment-resistive Terminals with Transistors (without detection functions) Collect a variety of data from maintenance systems without influencing control systems and productivity. Communications power supply voltage monitor, deterioration due to aging, operating time data, and other information can be easily collected and managed via the network. Locations of problems can be easily identified. Single action Models with 8 Input, 8 Output, or 16 I/O Points Added to the Lineup Remote I/O Terminals with IP67 High Environmental Resistance Terminals with 16 Inputs or Outputs Remote I/O Terminals with Transistors DRT2-ID08(-1)/OD08(-1)/ MD16(-1) Environment-resistive Terminals with Transistors DRT2-ID04CL(-1)/OD04CL(-1)/ ID08CL(-1)/OD08CL(-1)/MD16CL(-1)/ HD16CL(-1)/WD16CL(-1) MIL Connector Terminals with Transistors DRT2-ID16ML(-1)/ OD16ML(-1)/ ID16MLX(-1)/ OD16MLX(-1) First Board-type Smart Slave Terminals User boards attach easily to the DRT2- D32V(-1) using screws. Wiring is completed in a single action. No screw tightening required. Removable terminal blocks. Advanced models detect ground faults and broken lines in I/O wiring. Applicable wire sizes range from AWG24 to AWG16 (0.2 to 1.25 mm2 dia.) Includes industry-standard e-CON connector that can be used to connect prewired sensors without using special tools. (The OMRON XN2 Connector can be used.) The DRT2-AD04H offers high resolution at 1/30,000 (full scale) and insulation between input channels. The DRT2-AD04 and DRT2-DA02 support a wide variety of data sampling function, including scaling, peak/bottom hold, top/valley hold, comparator, integral, and differential operation functions. Offers basically the same functions as Analog Input Terminals, such as scaling and comparators. Also provides functions that are available only from Temperature Input Terminals, such as the time in a preset temperature range and temperature difference detection between input channels. Monitoring and setting of Temperature Controller from PLC. Batch download of all Temperature Controller parameters from Configurator. Frequencies and other specifications can be designated from PLC. Monitor-related maintenance possible, including output current (torque) error detection/trace, operation monitor, and general- purpose I/O read. I/O points can be extended by adding Expansion Units. One-step relay exchange Operation time monitor function enabled by combining Remote I/O Terminals with Expansion I/O Units. High resistance to environments (IP67). Detecting shorts in the sensor power supply is also possible. The 3-tier Terminal Block means that wiring locations are easy to find with no wiring to intermediate terminals. Ultra-small 32-point remote terminals (35 x 60 x 80 mm (W x D x H)). Smart Slave functions provide robust support for effective maintenance and monitoring device operation status. The terminals conform to IP67 and use materials selected for resistance to oil and spattering. Models with two-output connector are also available to improve ease of connection with hydraulic valve devices. Connection with an array of I/O interfaces is achieved by combining adaptor boards for D-Sub or other interfaces. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |