ADM1032ARM bảng dữ liệu(PDF) 10 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADM1032ARM bảng dữ liệu(HTML) 10 Page - Analog Devices |
|
10 / 12 page ![]() REV. 0 ADM1032 –10– 1. SMBALERT pulled low. 2. Master initiates a read operation and sends the Alert Response Address (ARA = 0001 100). This is a general call address that must not be used as a specific device address. 3. The device whose ALERT output is low responds to the Alert Response Address and the master reads its device address. As the device address is seven bits, an LSB of ‘1’ is added. The address of the device is now known and it can be inter- rogated in the usual way. 4. If more than one device’s ALERT output is low, the one with the lowest device address, will have priority, in accordance with normal SMBus arbitration. 5. Once the ADM1032 has responded to the Alert Response Address, it will reset its ALERT output, provided that the error condition that caused the ALERT no longer exists. If the SMBALERT line remains low, the master will send ARA again, and so on until all devices whose ALERT outputs were low have responded. LOW-POWER STANDBY MODE The ADM1032 can be put into a low-power standby mode by setting bit 6 of the Configuration Register. When Bit 6 is low, the ADM1032 operates normally. When Bit 6 is high, the ADC is inhibited, and any conversion in progress is terminated without writing the result to the corresponding value register. The SMBus is still enabled. Power consumption in the standby mode is reduced to less than 10 µA if there is no SMBus activity, or 100 µA if there are clock and data signals on the bus. When the device is in standby mode, it is still possible to initiate a one-shot conversion of both channels by writing XXh to the One-Shot Register (address 0Fh), after which the device will return to standby. It is also possible to write new values to the limit regis- ter while it is in standby. If the values stored in the temperature value registers are now outside the new limits, an ALERT is generated even though the ADM1032 is still in standby. THE ADM1032 INTERRUPT SYSTEM The ADM1032 has two interrupt outputs, ALERT and THERM. These have different functions. ALERT responds to violations of software-programmed temperature limits and is maskable. THERM is intended as a “fail-safe” interrupt output that cannot be masked. If the temperature goes equal to or below the lower temperature limit, the ALERT pin will be asserted low to indicate an out-of-limit condition. If the temperature is within the programmed low and high temperature limits, no interrupt will be generated. If the temperature exceeds the high temperature limit, the ALERT pin will be asserted low to indicate an over temperature condition. A local and remote THERM limit, may be programmed into the device to set the temperature limit above which the over temperature THERM pin will be asserted low. This temperature limit should be equal to or greater than the high temperature limit programmed. The behavior of the high limit and THERM limit is as follows: 1. If either temperature measured exceeds the high temperature limit, the ALERT output will assert low. 2. If the local or remote temperature continues to increase and either one exceeds the THERM limit, the THERM output asserts low. This can be used to throttle the CPU clock or switch on a fan. A THERM Hysteresis Value is provided to prevent a cooling fan cycling on and off. The power-on default value is 10 °C but this may be reprogrammed to any value after power-up. This hyster- esis value applies to both the local and remote channels Using these two limits in this way allows the user to gain maxi- mum performance from the system by only slowing it down, should it be at a critical temperature. The THERM signal is open drain and requires a pull-up to VDD. The THERM signal must always be pulled up to the same power supply as the ADM1032, unlike the SMBus signals (SDATA, SCLK, and ALERT) which may be pulled to a differ- ent power rail, usually that of the SMBus controller. 100 C 90 C 80 C 70 C 60 C 50 C 40 C THERM LOCAL THERM LIMIT LOCAL THERM LIMIT –HYSTERESIS TEMPERATURE Figure 5. Operation of the THERM Output Table IX. THERM HYSTERESIS Sample Values THERM HYSTERESIS Binary Representation 0 °C 0 000 0000 1 °C 0 000 0001 10 °C 0 000 1010 SENSOR FAULT DETECTION At the D+ input the ADM1032 has a fault detector that detects if the external sensor diode is open-circuit. This is a simple voltage comparator that trips if the voltage at D+ exceeds VDD – 1 V (typical). The output of this comparator is checked when a conversion is initiated, and sets Bit 2 of the Status Register if a fault is detected. If the remote sensor voltage falls below the normal measuring range, for example due to the diode being short-circuited, the ADC will output –128 (1000 0000). Since the normal operating temperature range of the device only extends down to 0 °C, this output code should never be seen in normal operation, so it can be interpreted as a fault condition. Since it will be outside the power-on default low temperature limit (0 °C) and any low limit that would normally be programmed, a short-circuit sensor will cause an SMBus alert. In this respect the ADM1032 differs from and improves upon, competitive devices that output zero if the external sensor goes short-circuit. These devices can misinterpret a genuine 0 °C measurement as a fault condition. When the D+ and D– lines are shorted together, an ALERT will always be generated. This is because the remote value regis- ter reports a temperature value of –128 °C. Since the ADM1032 performs a less-than or equal-to comparison with the low limit, an ALERT is generated even when the low limit is set to its minimum of –128 °C. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |