2 / 4 page ![]() MJ802 2 Motorola Bipolar Power Transistor Device Data ELECTRICAL CHARACTERISTICS (TC = 25_C unless otherwise noted) Characteristic Symbol Min Max Unit OFF CHARACTERISTICS Collector–Emitter Breakdown Voltage(1) (IC = 200 mAdc, RBE = 100 Ohms) BVCER 100 — Vdc Collector–Emitter Sustaining Voltage(1) (IC = 200 mAdc) VCEO(sus) 90 — Vdc Collector–Base Cutoff Current (VCB = 100 Vdc, IE = 0) (VCB = 100 Vdc, IE = 0, TC = 150_C) ICBO — — 1.0 5.0 mAdc Emitter–Base Cutoff Current (VBE = 4.0 Vdc, IC = 0) IEBO — 1.0 mAdc ON CHARACTERISTICS(1) DC Current Gain(1) (IC = 7.5 Adc, VCE = 2.0 Vdc) hFE 25 100 — Base–Emitter “On” Voltage (IC = 7.5 Adc, VCE = 2.0 Vdc) VBE(on) — 1.3 Vdc Collector–Emitter Saturation Voltage (IC = 7.5 Adc, IB = 0.75 Adc) VCE(sat) — 0.8 Vdc Base–Emitter Saturation Voltage (IC = 7.5 Adc, IB = 0.75 Adc) VBE(sat) — 1.3 Vdc DYNAMIC CHARACTERISTICS Current Gain — Bandwidth Product (IC = 1.0 Adc, VCE = 10 Vdc, f = 1.0 MHz) fT 2.0 — MHz (1)Pulse Test: Pulse Width v 300 µs, Duty Cycle v 2.0%. IC, COLLECTOR CURRENT (AMP) TJ = 175° C 3.0 IC, COLLECTOR CURRENT (AMP) 1.0 2.0 0.7 1.0 0.5 0.1 Figure 2. DC Current Gain Figure 3. ‘‘On” Voltages VBE(sat) @ IC/IB = 10 VCE = 2.0 V 25 °C – 55 °C TJ = 25°C 0.03 0.1 0.2 0.3 0.5 10 20 30 0.3 0.2 0.05 2.0 3.0 5.0 DATA SHOWN IS OBTAINED FROM PULSE TESTS AND ADJUSTED TO NULLIFY EFFECT OF ICBO. 2.0 1.8 1.4 1.6 1.2 0 1.0 0.8 0.6 0.4 0.2 1.0 0.03 0.1 0.2 0.3 0.5 10 20 30 0.05 2.0 3.0 5.0 VBE @ VCE = 2.0 V VCE(sat) @ IC/IB = 10 50 1.0 VCE, COLLECTOR–EMITTER VOLTAGE (VOLTS) 5.0 20 10 1.0 0.2 10 Figure 4. Active Region Safe Operating Area 100 5.0 2.0 0.5 0.1 20 2.0 3.0 100 50 30 SECONDARY BREAKDOWN LIMITED BONDING WIRE LIMITED THERMAL LIMITATIONS TC = 25°C PULSE DUTY CYCLE ≤ 10% TJ = 200° C 100 µs 1.0 ms 5.0 ms dc The Safe Operating Area Curves indicate IC – VCE limits below which the device will not enter secondary breakdown. Collector load lines for specific circuits must fall within the applicable Safe Area to avoid causing a catastrophic failure. To insure operation below the maximum TJ, power tempera- ture derating must be observed for both steady state and pulse power conditions. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |