| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
AD9915BCPZ bảng dữ liệu(PDF) 43 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9915BCPZ bảng dữ liệu(HTML) 43 Page - Analog Devices |
|
43 / 48 page ![]() Data Sheet AD9915 Rev. A | Page 43 of 48 Bit(s) Mnemonic Description 12 Open Open. 11 SYNC_CLK enable 0 = the SYNC_CLK pin is disabled and forced to a static Logic 0 state; the internal clock signal continues to operate and provide timing to the data assembler. 1 = the internal SYNC_CLK signal appears at the SYNC_CLK pin (default). 10 SYNC_CLK invert 0 = normal SYNC_CLK polarity; Q data associated with Logic 1, I data with Logic 0 (default). 1 = inverted SYNC_CLK polarity. 9 SYNC_OUT enable 0 = the SYNC_OUT pin is disabled; static Logic 0 output. 1 = the SYNC_OUT pin is enabled. 8 SYNC out/in mux enable 0 = the SYNC_OUT signal is routed to the SYNC_OUT pin. 1 = the SYNC_IN signal is routed to the SYNC_OUT pin. [7:0] Open Open. Control Function Register 3 (CFR3)—Address 0x02 Table 19. Bit Descriptions for CFR3 Bit(s) Mnemonic Description [31:23] Open Open. 22 Input divider reset 0 = disables input divider reset function. 1 = initiates a input divider reset. [21:20] Input divider Divides the input REF CLK signal by one of four values (1, 2, 4, 8). 19 Doubler enable 0 = disables the doubler feature. 1 = enables the doubler feature. Must have the doubler clock edge bit set to Logic 1 to utilize this feature. 18 PLL enable 0 = disables the internal PLL. 1 = the internal PLL is enabled and the output generates the system clock. The PLL must be calibrated when enabled via VCO calibration in Register CFR1, Bit 24. 17 PLL ref disable This bit should remain Logic 0 (default). 16 Doubler clock edge 0 = disables the internal doubler circuit. 1 = enables the doubler circuit. Must have doubler enable bit set to Logic 1 to utilize this feature. [15:8] Feedback divider N Sets the feedback divider of the PLL. The divider range is 8× to 255×. Bits[15:8] = 0000 = 8×, 0001 = 9× … 1111 = 255× 7 Open Open. 6 Manual I CP selection 0 = the internal charge pump current is chosen automatically during the VCO calibration routine (default). 1 = the internal charge pump is set manually per Table 7. [5:3] I CP Manual charge pump current selection. See Table 7. 2 Lock detect enable 0 = disables PLL lock detection. 1 = enables PLL lock detection. [1:0] Minimum LDW Selects the number of REF CLK cycles that the phase error (at the PFD inputs) must remain within before a PLL lock condition can be read back via Bit 24 in Register 0x00. 00 = 128 REF CLK cycles 01 = 256 REF CLK cycles 10 = 512 REF CLK cycles 11 = 1024 REF CLK cycles |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |