45 / 61 page ![]() GS9060 Data Sheet 22208 - 8 January 2007 45 of 61 3.10.5.3 Lock Error Detection The LOCKED pin of the GS9060 indicates the lock status of the reclocker and lock detect blocks of the device. Only when the LOCKED pin is asserted HIGH has the device correctly locked to the received data stream, Section 3.6 on page 28. The GS9060 will also indicate lock error to the host interface when LOCKED = LOW by setting the LOCK_ERR bit in the ERROR_STATUS register HIGH. Table 3-12: Host Interface Description for EDH Calculation Range Registers Register Name Bit Name Description R/W Default AP_LINE_START_F0 Address: 12h 15-10 Not Used 9-0 AP_LINE_START_F0[9:0] Field 0 Active Picture start line data used to set EDH calculation range outside of SMPTE RP 165 values. R/W 0 AP_LINE_END_F0 Address: 13h 15-10 Not Used 9-0 AP_LINE_END_F0[9:0] Field 0 Active Picture end line data used to set EDH calculation range outside of SMPTE RP 165 values. R/W 0 AP_LINE_START_F1 Address: 14h 15-10 Not Used 9-0 AP_LINE_START_F1[9:0] Field 1 Active Picture end line data used to set EDH calculation range outside of SMPTE RP 165 values. R/W 0 AP_LINE_END_F1 Address: 15h 15-10 Not Used 9-0 AP_LINE_END_F1[9:0] Field 1 Active Picture end line data used to set EDH calculation range outside of SMPTE RP 165 values. R/W 0 FF_LINE_START_F0 Address: 16h 15-10 Not Used 9-0 FF_LINE_START_F0[9:0] Field 0 Full Field start line data used to set EDH calculation range outside of SMPTE RP 165 values. R/W 0 FF_LINE_END_F0 Address: 17h 15-10 Not Used 9-0 FF_LINE_END_F0[9:0] Field 0 Full Field start line data used to set EDH calculation range outside of SMPTE RP 165 values. R/W 0 FF_LINE_START_F1 Address: 18h 15-10 Not Used 9-0 FF_LINE_START_F1[9:0] Field 1 Full Field start line data used to set EDH calculation range outside of SMPTE RP 165 values. R/W 0 FF_LINE_END_F1 Address: 19h 15-10 Not Used 9-0 FF_LINE_END_F1[9:0] Field 1 Full Field end line data used to set EDH calculation range outside of SMPTE RP 165 values. R/W 0 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |