| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
MAX6683EVCMODU bảng dữ liệu(PDF) 5 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX6683EVCMODU bảng dữ liệu(HTML) 5 Page - Maxim Integrated Products |
|
5 / 8 page ![]() MAX6683 Evaluation System/Evaluation Kit _______________________________________________________________________________________ 5 5 ____________________________________________________________________________________ Detailed Description User-Interface Panel The user interface is easy to operate using the mouse, or by using the tab key to navigate with the arrow keys. The checkboxes, edit fields, and radio buttons corre- spond to bits in the internal registers. By clicking on them, the correct SMBus write operation is generated to update the registers. The program monitors for an alert interrupt and continu- ally polls the device for new temperature, voltage, and status data. To disable the continuous polling of data, uncheck the Automatic Read checkbox. To change the temperature or voltage threshold comparison regis- ters, select the appropriate data field and type in the new value. Pressing Enter, after typing in the new val- ues, updates the internal registers. The message ALERT appears whenever an interrupt condition occurs. To clear the interrupt, first eliminate the condition that caused it and then click on Read Status. Simple SMBus Commands There are two methods for communicating with the MAX6683: through the normal user-interface panel or through the SMBus commands available from pressing the MAXSMBus.. button. A display appears that allows the SMBus protocols, such as Read Byte and Write Byte, to be executed. To stop normal user-interface execution so that it does not override the manually set values, turn off the update timer that slaves the pro- gram to the conversion rate by unchecking the Automatic Read checkbox. The SMBus dialog boxes accept numeric data in bina- ry, decimal, or hexadecimal. Hexadecimal numbers should be prefixed by $ or 0x. Binary numbers must be exactly eight digits. Note: In places where the slave address asks for an 8- bit value, it must be the 7-bit slave address of the MAX6683 as determined by the address pin (ADD) with the last bit set to 1 for a read operation and 0 for a write. Data Logging Check the Data Logging checkbox to activate data logging. Data logging saves temperature, voltage, and status data to a text file that includes a time/date stamp next to each data point. If Automatic Read is enabled, data is sampled at 2Hz; however, the data is logged to the file only if the temperature, voltage, or status change. This slows the growth of the data-logging file. When Automatic Read is disabled, the data is logged each time the Read All button is clicked. To stop data logging, uncheck the Data Logging checkbox. Jumper and Switch Settings Jumper 1 (JU1) sets the MAX6683 slave address. The default address is 0010 101 (ADD = VCC); see Table 1 for a complete list of addresses. The slide switch, SW1, provides a means to force a reset. This switch disables power to the device. Evaluating the MAX6652 The MAX6683 EV kit can also evaluate the MAX6652. Remove the MAX6683 from the board and install the MAX6652. The MAX6652 and MAX6683 monitor different voltages. See Table 2. When evaluating the MAX6652 with the MAX6683 soft- ware, the voltages displayed for the supply voltage (VCC), the 1.8V nominal voltage, and the 5V nominal voltage are incorrect. However, the ADC output code, shown in parentheses next to the voltage, is correct. Use the equa- tions shown below to calculate the actual voltages: . V V ADC output code Voltage on pin V ADC output code Voltage on pin V ADC output code CC = × = × = × 5 192 1 12 192 3 33 192 Table 2. Voltage Monitor Differences Between MAX6652 and MAX6683 SHUNT LOCATION ADD CONNECTION MAX6683 ADDRESS 0x28 To GND 0010 100Y 0x2A To VCC 0010 101Y 0x2C To SDA 0010 110Y 0x2E To SCL 0010 111Y Table 1. JU1 Shunt Settings for SMBus Address Note: The first 7 bits shown are the address. Y (bit 0) is the SMBus read/write bit. This bit is a 1 for a read operation and zero for a write. PIN MAX6652 (V) MAX6683 (V) 10 (VCC) 5 3.3 1 12 1.8 3 3.3 5 |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |