| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
PCA9561 bảng dữ liệu(PDF) 6 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
PCA9561 bảng dữ liệu(HTML) 6 Page - NXP Semiconductors |
|
6 / 17 page ![]() Philips Semiconductors Product data sheet PCA9561 Quad 6-bit multiplexed I2C EEPROM DIP switch 2004 May 17 6 EXTERNAL CONTROL SIGNALS The Write Protect (WP) input is used to control the ability to write the content of the non-volatile registers. If the WP signal is logic 0, the I2C-bus will be able to write the contents of the non-volatile registers. If the WP signal is logic 1, data will not be allowed to be written into the non-volatile registers. In this case, the slave address and the command code will be acknowledged but the following data bytes will not be acknowledged and the EEPROM is not updated. The factory default for the contents of the non-volatile register are all logic 0. These stored values can be read or written using the I2C-bus (described in the next section). The WP, MUX_IN*, and MUX_SELECT signals have internal pull-up resistors. See the DC and AC Characteristics for hysteresis and signal spike suppression figures. Function Table1 WP MUX_SELECT COMMANDS 0 X Write to the non-volatile registers through I2C-bus allowed 1 X Write to the non-volatile registers through I2C-bus not allowed X 0 MUX_OUT from EEPROM byte 0–3 (EEPROM selected through I2C – see Table 2) X 1 MUX_OUT from MUX_IN inputs NOTE: 1. This table is valid when not overridden by I2C control register. POWER-ON RESET (POR) When power is applied to VDD, an internal power-on reset holds the PCA9561 in a reset state until VDD has reached VPOR. At that point, the reset condition is released and the PCA9561 volatile registers and state machine will initialize to their default states. The MUX_OUT pin values depend on the MUX_SELECT logic level: – if MUX_SELECT = 0, the MUX_OUT pin output values will equal the previously stored EEPROM byte 0 values regardless of the last non-volative EEPROM byte selected by the command byte prior to power down. – if MUX_SELECT = 1, the MUX_OUT output values will equal the MUX_IN pin input values as shown in the Function Table. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |