công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

EVM142AHF bảng dữ liệu(PDF) 13 Page - Semtech Corporation

tên linh kiện EVM142AHF
Giải thích chi tiết về linh kiện  Per Pin timing Deskew w 4x2 Cross Point Switch
PDF  19 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
nhà sản xuất  SEMTECH [Semtech Corporation]
Trang chủ  http://www.semtech.com
Logo SEMTECH - Semtech Corporation

EVM142AHF bảng dữ liệu(HTML) 13 Page - Semtech Corporation

Back Button EVM142AHF Datasheet HTML 9Page - Semtech Corporation EVM142AHF Datasheet HTML 10Page - Semtech Corporation EVM142AHF Datasheet HTML 11Page - Semtech Corporation EVM142AHF Datasheet HTML 12Page - Semtech Corporation EVM142AHF Datasheet HTML 13Page - Semtech Corporation EVM142AHF Datasheet HTML 14Page - Semtech Corporation EVM142AHF Datasheet HTML 15Page - Semtech Corporation EVM142AHF Datasheet HTML 16Page - Semtech Corporation EVM142AHF Datasheet HTML 17Page - Semtech Corporation Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 19 page
background image
13
 2000 Semtech Corp.
www.semtech.com
EDGE HIGH-PERFORMANCE PRODUCTS
Edge142
Application Information (continued)
EL11 Clock Spreader Tpd vs. 1%-99% Duty Cycle
Duty Cycle [%] (Period=100 ns)
-100
-80
-60
-40
-20
0
20
40
60
80
100
0
1 02 0
3 0
4 05 06 0
7 080
9 0
1 0 0
Tpd+ Error
Tpd- Error
Edge 142 Tpd+ vs. 1%-99% Duty Cycle
Duty Cycle [%] (Period=100 ns)
-100
-80
-60
-40
-20
0
20
40
60
80
100
0
1 0
2 03 04 0
5 06 07 0
809 0 1 0 0
Tpd+ Error, +0.1V
Tpd+ Error, -0.1V
Tpd+ Error, -0.3V
Tpd+ Error, -0.7V
Tpd+ Error, -0.9V
Tpd+ Error, -1.1V
Tpd+ Error, -1.3V
REXT2=2.94K
Edge 142 Tpd- vs. 1%-99% Duty Cycle
Duty Cycle [%] (Period=100 ns)
-100
-80
-60
-40
-20
0
20
40
60
80
100
0
1 0
2 03 04 0
5 06 07 0
809 0 1 0 0
Tpd- Error, +0.1V
Tpd- Error, -0.1V
Tpd- Error, -0.3V
Tpd- Error, -0.7V
Tpd- Error, -0.9V
Tpd- Error, -1.1V
Tpd- Error, -1.3V
REXT2=2.94K
Prop Delay vs. Duty Cycle
The 142 shows very little change in propagation delay
vs. input duty cycle. The following three charts show
the variation in the prop delay of a rising edge and a
falling edge as the duty cycle is varied from 1% to 99%.
Since the input signal period is 100 ns, a 1% duty cycle
corresponds to a 1 ns positive input pulse. A 99% duty
cycle corresponds to a 1 ns negative input pulse.
The first chart shows the Motorola 10EL11 clock
spreader timing error for both the rising and falling edge.
This information is used as a reference to compare the
142 against.
The second and third charts show the 142 under identical
conditions. The data is broken out into one chart for the
rising edge and a separate chart for the falling edge. In
addition, the timing error is listed over the entire delay
range of the 142.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com