16 / 28 page ![]() SPI Driver for Enhanced Relay Control SPIDER - TLE7243SL Protection Functions Datasheet 16 Rev. 1.0, 2009-09-30 6 Protection Functions The device provides embedded protective functions. Integrated protection functions are designed to prevent IC destruction under fault conditions described in this datasheet. Fault conditions are considered as “outside” normal operating range. Protection functions are not designed for continuous repetitive operation. 6.1 Over Load Protection The SPIDER - TLE7243SL is protected in case of over load or short circuit of the load. After time tOFF(OVL), the over loaded channel n switches off and the according diagnosis flag Dn is set.The channel can be switched on after clearing the diagnosis flag. Please refer to Figure 7 for details. Figure 7 Shut down at over load The current sink to ground ensures that the channels switch off in case of open input pin. The zener diode protects the input circuit against ESD pulses. After power-on reset, the device enters idle mode. 6.2 Over Temperature Protection A temperature sensor for each channel causes an overheated channel n to switch off to prevent destruction and the according diagnosis flag Dn is set. The channel can be switched on after clearing the diagnosis flag. Please refer to Chapter 7.1 for information on diagnosis features. 6.3 Reverse Polarity Protection In case of reverse polarity, the intrinsic body diode of the power transistor causes power dissipation. The reverse current through the intrinsic body diode of the power transistor has to be limited by the connected load. The V DD and V DDA supply pins must be protected against reverse polarity externally. The over temperature and over load protection is not active during reverse polarity. IN1 IOUT1 t t OverLoad.emf tOFF(OVL) I OUT(OVL) D1 = 1b IN1 = 01b D1 = 0b D1 = 0b Program OUT 1 to STANDBY and to IN1 again |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |