| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
IR3523MPBF bảng dữ liệu(PDF) 22 Page - International Rectifier |
|
|
|||||||||||||||||||||||||||||
IR3523MPBF bảng dữ liệu(HTML) 22 Page - International Rectifier |
|
22 / 37 page ![]() IR3523 Page 22 of 37 June 20, 2008 OUTPUT VOLTAGE (VO) VID DOWN NORMAL OPERATION VDAC VID OV THRESHOLD VDAC + 130mV 1.73V NORMAL OPERATION VID UP LOW VID VDAC 50mV 50mV Figure 15 - Over-voltage protection during dynamic VID Open Remote Sense Line Protection If either remote sense line VOSENX+ or VOSENX- is open, the output of Remote Sense Amplifier (VOUTX) drops. The IR3523 continuously monitors the VOUTX pin and if VOUTX is lower than 200 mV, two separate pulse currents are applied to the VOSENX+ and VOSENX- pins to check if the sense lines are open. If VOSENX+ is open, a voltage higher than 90% of V(VCCL) will be present at VOSENX+ pin and the output of Open Line Detect Comparator will be high. If VOSENX- is open, a voltage higher than 400mV will be present at VOSENX- pin and the Open Line Detect Comparator output will be high. With either sense line open, the Open Sense Line Fault Latch will be set to force the error amplifier output low and immediately shut down the converter. SS/DELX will be discharged and the Open Sense Fault Latch can only be reset by cycling the power to VCCL. Open Daisy Chain Protection IR3523 checks the daisy chain every time it powers up. It starts a daisy chain pulse on the PHSOUT pin and detects the feedback at PHSIN pin. If no pulse comes back after 32 CLKOUT pulses, the pulse is restarted again. If the pulse fails to come back the second time, the open daisy chain fault is registered, and SS/DEL is not allowed to charge. The fault latch can only be reset by cycling the power to VCCL. After powering up, the IR3523 monitors PHSIN pin for a phase input pulse equal or less than the number of phases detected. If PHSIN pulse does not return within the number of phases in the converter, another pulse is started on PHSOUT pin. If the second started PHSOUT pulse does not return on PHSIN, an open daisy chain fault is registered. Phase Number Determination After a daisy chain pulse is started, the IR3523 checks the timing of the input pulse at PHSIN pin to determine the phase number. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |