| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
ST10F276Z5 bảng dữ liệu(PDF) 228 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST10F276Z5 bảng dữ liệu(HTML) 228 Page - STMicroelectronics |
|
228 / 239 page ![]() Known limitations ST10F276Z5 228/239 24 Known limitations This section describes the functional and electrical limitations identified on the CEG silicon revision of the ST10F276Z5. The major revision of the device is contained in the device identification register, IDCHIP, located at address F07Ch. For Cxx versions, IDCHIP is set to 1143h. 24.1 Functional limitations The function limitations identified on the ST10F276Z5 are the following: ● Injected conversion stalling the A/D converter (see Section 24.1.1: Injected conversion stalling the A/D converter) ● Concurrent transmission requests in DAR mode (C-CAN module) (see Section 24.1.2: Concurrent transmission requests in DAR-mode (C-CAN module)) ● Disabling transmission requests (see Section 24.1.3: Disabling the transmission requests (C-CAN module)) ● Spurious BREQ pulse in slave mode during external bus arbitration phase (see Section 24.1.4: Spurious BREQ pulse in slave mode during external bus arbitration phase) ● Executing PWRDN instructions (see Section 24.1.5: Executing PWRDN instructions) ● Behavior of capture/compare (CAPCOM) outputs in COMPARE mode 3 (see Section 24.1.6: Behavior of CAPCOM outputs in COMPARE mode 3) 24.1.1 Injected conversion stalling the A/D converter Description The A/D converter is stalled and no further conversions are performed when a new injection request is issued before the CPU reads the ADDAT2 register (that is when the CPU has not read the result of the previous injection request). Workarounds and recovery actions The following actions allow to unlock the A/D converter: 1. Read the ADDAT2 register twice at the end of every injected conversion. This action also prevents the ADC from being stalled. 2. Disable and then enable again the wait for read mode. Application conditions This problem occurs if all the following conditions are fulfilled: ● Injection requests are hardware triggered (via CapCom CC31). ● The results of injected conversions are read by performing a PEC transfer. This prevents from reading twice the ADDAT2 register by software. ● A high level task is disabling the PEC transfer for a long time (time needed for 2 analog conversions plus time between 2 injection requests). |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |