3 / 6 page ![]() Low-Cost 61⁄2-Digit Multimeters 3 BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) Specifications DC Specifications DC Voltage ± (ppm of reading + ppm of range)1 DC Current ± (ppm of reading + ppm of range) Resistance (4- and 2-Wire) ± (ppm of reading + ppm of range) Diode Test1 Range Resolution Test Current Accuracy 10 V 10 µV 100 µA, 1 mA Add 50 ppm of reading and 50 ppm of range to 10 VDC voltage specifications. 1Can be used to test p-n junctions, LEDs, or zener diodes up to 10 V.= Resolution (Digits) Reading Rate1 (S/s) Aperture Time (NPLC) RMS Noise2 (ppm of range) 61⁄2 0.6 (0.5) 100 0.06 6 (5) 10 0.2 10 (8.33) 6 0.25 51⁄2 30 (25) 2 0.4 60 (50) 1 0.55 900 0.06 1.7 1,500 0.04 2.5 41⁄2 3,000 0.02 11.5 1 Specified for 60 Hz and (50 Hz) operation 2 Measured on the 10 V range Range Resolution Input Resistance4 24-Hour2, Tcal ±1 °C 90-Day, Tcal ±5 °C 1-Year, Tcal ±5 °C Tempco (0 to 55 °C) 100 mV3 100 nV >10 G Ω, 10 MΩ 30 + 30 65 + 35 90 + 35 5 + 2 1 V 1 µV >10 G Ω, 10 MΩ 20 + 6 65 + 7 90 + 7 5 + 0.2 10 V 10 µV >10 G Ω, 10 MΩ 15 + 5 65 + 6 90 + 6 5 + 0.2 100 V 100 µV 10 M Ω 20 + 6 75 + 7 110 + 7 6 + 0.2 300 V 1 mV 10 M Ω 20 + 20 75 + 20 110 + 20 6 + 0.5 1ppm (part per million) = 0.0001% 2Relative to external calibration source 3With offset nulling 4Default input resistance is 10 M Ω Tcal = temperature at which last external calibration was performed NI factory calibration is 23 ˚C ± 1 ˚C Tempco = temperature coefficient Range Resolution Burden Voltage (typical) 24-Hour2,Tcal ±1 °C 90-Day, Tcal ±5 °C 1-Year, Tcal ±5 °C Tempco (0 to 55 °C) 10 mA 10 nA <60 mV 50 + 100 300 + 200 500 + 200 30 + 20 100 mA 100 nA <0.6 V 100 + 40 300 + 50 500 + 50 30 + 5 1 A 1 µA <0.35 V 500 + 60 800 + 100 1000 + 100 65 + 10 3 A 3 µA <1 V 10001 + 200 12001 + 200 12001 + 200 65 + 20 1Add 650 ppm/A of reading for currents above 1.5 A 2Relative to external calibration source Range Resolution Test Current 24-Hour1, Tcal ±1 °C 90-Day,Tcal ±5 °C 1-Year, Tcal ±5 °C Tempco (0 to 55 °C) 100 Ω 100 µ Ω 1 mA 30 + 30 95 + 40 110 + 40 8 + 3 1 k Ω 1 m Ω 1 mA 20 + 6 95 + 10 110 + 10 8 + 1 10 k Ω 10 m Ω 100 µA 20 + 6 95 + 10 110 + 10 8 + 1 100 k Ω 100 m Ω 10 µA 20 + 6 95 + 10 110 + 10 8 + 1 1 M Ω 1 Ω 5 µA 20 + 10 110 + 12 125 + 12 10 + 1 10 M Ω 10 Ω 500 nA 150 + 10 400 + 12 500 + 12 30 + 2 100 M Ω 100 Ω 500 nA || 10 M Ω 2000 + 20 6000 + 40 8000 + 40 400 + 4 1Relative to external calibration source Specifications are for 4-wire measurements. For 2-wire measurements, perform offset nulling or add 200 m Ω to reading. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |