7 / 14 page ![]() SA8807A sames 7/14 Diagram 1 2. Addressing and Read/Write Mode Select To access the SA8807A, a control byte has to be received first (after CE goes active). This byte contains the information to initiate either a Read or Write mode and an address. The following bytes contain data until CE becomes inactive. Address/Control Byte: The Address and Control Byte is the first byte sent after CE goes active. To send another address, CE must first go inactive before going active again. If the CE remains high, the device automatically increments the address, for the following byte. W/R = "1" One or more write cycles to be sent. W/R = "0" Inititates one or more read cycles. A5 - A0: Address 5 to Address 0 selects the 6-bit HEX Address of RAM. (See LCD Character Mapping) SCK may be either polarity. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|